Gage Bilt GB208-625 Original Instructions Manual - Page 13

Browse online or download pdf Original Instructions Manual for Rivet Tools Gage Bilt GB208-625. Gage Bilt GB208-625 20 pages.

Note: Gage Bilt does not recommend using a pneumatic lubricator or adding pneumatic oil to the air inlet on our tools or powerunits.
Stroke limiters are designed for the protection of the operator and equipment. Failure to operate tool with a stroke limiter as required
will result in damage to the nose assembly or tool and may result in personal injury. If you are unsure your nose assembly requires a
stroke limiter, contact Gage Bilt.
An extra relief valve (for use when a long-stroke tool is required), is included with each tool.
1. To install or remove stroke limiter (208112) on piston assembly (208111), see overhaul instructions (#1 thru #7) on pg.12.
2. To increase stroke to .750" (19 mm), remove stroke limiter (208112) and relief valve (208109) from piston assembly (208111).
Install the extra relief valve (208110) (flats to rear of the tool) in the piston assembly (208111). Note positions and locations
shown below.
Do NOT position relief valve
flats to front of tool.
GB208-625 / GB208-625A
STROKE LIMITER - INSTALLATION & REMOVAL
Stroke Limiter (208112)
Relief Valve (208110)
Front of tool.
Rear of tool.
Images may not
reflect actual tool.
13
Stroke Limiter (208112)
Piston Assembly (208111)
Position relief valve
flats to REAR of tool.
9/16 REV 6/22