Dyna-Glo RA18LPDGD User Manual - Page 14

Browse online or download pdf User Manual for Heater Dyna-Glo RA18LPDGD. Dyna-Glo RA18LPDGD 16 pages. Propane construction heater
Also for Dyna-Glo RA18LPDGD: User Manual (19 pages)

Dyna-Glo RA18LPDGD User Manual
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING (continued)
Problem
Gas odor even when control knob is
in OFF position.
Gas odor during combustion.
Heater shuts off on ODS.
Possible Cause
1. Gas leaks. Refer to front of page
Warnings.
2. Gas control defective.
1. Foreign matter in gas or on burner ports.
2. Heater burning vapors form paint,
impurities in air.
3. Gas leaks, refer to front page Warnings
1. Not enough fresh air is available.
2. Low gas pressure.
3. ODS pilot partially clogged.
1-877-475-5660
What To Do
1. Locate and correct leaks immediately.
2. Replace gas control
1. Check gas passage way and burner.
2. Ventilate room, stop storing and using
odor causing products near heater.
3. Locate and correct leaks immediately.
1. Open window.
2. Contact gas supplier.
3. Clean the pilot.
1-877-475-5660
14