Dyna-Glo LPFA125WH User's Manual And Operating Instructions - Page 3
Browse online or download pdf User's Manual And Operating Instructions for Gas Heater Dyna-Glo LPFA125WH. Dyna-Glo LPFA125WH 18 pages. Propane construction heater
PROPANE FORCED AIR CONSTRUCTION HEATERS
The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard
to anticipate every use which may be made of this heater.
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
Other standards govern the use of fuel gases and heat producing products in specific applications.
Your local authority can advise you about these.
IMPORTANT: READ THIS USER'S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING
TO OPERATE OR SERVICE THIS HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE
SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION AND CARBON MONOXIDE POISONING.
This is a direct-fired forced air construction heater for either indoor construction or outdoor use. Its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efficiency but still produces a small amount
of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
Input
R ating
Type
o f
G as
Gas
S upply
P ressure
t o
Regulator
M aximum
Minimum
( for
p urpose
o f
Input
A djustment)
Manifold
P ressure
Gas
C onsumption
Electrical
I nput
Amperage
L oad
U nload
Fan
L oad
Ignition
Spark
G ap
Size
( LxWxH)
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
PROPANE CONSTRUCTION HEATER
WARNING
: NOT FOR USE WITH DUCT WORK.
SPECIFICATIONS
30,000
B TU/hr
40,000
B TU/hr
60,000
B TU/hr
Propane
Cylinder
P ressure
Cylinder
P ressure
5psig
11"
W .C
1.4lbs/hr
0 .63
k g/hr
1.9lbs/hr
0 .86
k g/hr
2.8lbs/hr
1 .27
k g/hr
120V,
6 0Hz,
1 Ø
120V,
6 0Hz,
1 Ø
0.68amps
3550rpm
3000rpm
Piezo/Manual
S park
Continuous
S park
0.16"
( 4mm)
0.16"
( 4mm)
19.3"x8.3"x15.2"
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
(49.0x21.1x38.6)cm
CHECK WITH YOUR LOCAL FIRE SAFETY
70,000
B TU/hr
125,000
B TU/hr
Propane
Propane
Cylinder
P ressure
5psig
5psig
11"
W .C
11"
W .C
3.3lbs/hr
1 .5
k g/hr
5.8lbs/hr
2 .63
k g/hr
120V,
6 0Hz,
1 Ø
0.65amps
0.7amps
3570rpm
3580rpm
3300rpm
3300rpm
Continuous
S park
0.16"
( 4mm)
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
120,000
B TU/hr
150,000
B TU/hr
Propane
Cylinder
P ressure
5psig
11"
W .C
5.6lbs/hr
2 .54
k g/hr
7.0lbs/hr
3 ,18
k g/hr
120V,
6 0Hz,
1 Ø
0.7amps
3580rpm
3300rpm
Continuous
S park
0.11"
( 2.8mm)
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
3