Great Lakes Biostar Scan Operation Manual - Page 6
Browse online or download pdf Operation Manual for Dental equipment Great Lakes Biostar Scan. Great Lakes Biostar Scan 16 pages.
Reminder: Do not use material thicker than 5.0mm within the clamping mechanism. This
may cause the Biostar to malfunction while pressure is in the chamber. Always wear safety
glasses when using this machine and during all fabrication procedures.
Maintenance
A regular maintenance schedule should be followed. Proper maintenance will assure better
fabrication results. Refrain from using water in the Biostar machine. Water may cause certain
components to rust or corrode. When the machine is not being used, engage the clamping
frame to the chamber and position the chamber on the pellet cup. This prevents lab dust from
entering the pellet cup and chamber.
5
The reflective surface of the pressure chamber
should be cleaned regularly with a damp cloth
to achieve optimum results.
Pellets will become dirty with regular use.
Clean pellets by placing them in a strainer and
rinsing with hot water. Spread pellets on a
towel and let air dry before placing them back
in the Biostar. Check pellets monthly, discard
and replace pellets in the bottom third of the
cup.
Also, clean the pellet drawer space to allow for
proper insertion of the drawer.