Hi-Force HTWP21 Series Operating Instructions Manual - Page 4

Browse online or download pdf Operating Instructions Manual for Tools Hi-Force HTWP21 Series. Hi-Force HTWP21 Series 8 pages. Air driven torque pumps

Prepared by:-
Mark Dalley
REV NO:- 002
ECO:- 3942
NB if very long hoses are employed (greater than 5 m) then this method will not be totally effective. Consult your
Hi-Force distributor for advice on pre-filling hoses.
Press and hold the advance button again and whilst doing so adjust the relief valve by turning the knob clockwise
until maximum working pressure (700 bar) is reached. Reduce the pressure by turning the knob anticlockwise. The
pressure setting can be locked at the desired value by tightening the wing nut under the adjusting knob clockwise.
The pump is now ready for use
Refer to torque wrench operating instructions for detailed information on the correct operation of these tools.

MAINTENANCE

The oil level in the reservoir should not be allowed to fall below the minimum level during use. Keep the
reservoir topped up with Hi-Force HFO46 oil. If the oil level does fall below the minimum level then air may
be drawn into the system and cause erratic operation.
Regularly inspect the air hoses for damage.
Oil should be replaced after approximately 500 working hours. Drain oil via drain plug (9)
Add viscosity grade 22 air line lubrication oil to reservoir (15) as required. Do not use hydraulic oil.
Drain water from air regulator filter bowl as required by depressing the valve on the bottom of the bowl.
TROUBLE SHOOTING
These pumps should be repaired only by authorised Hi-Force repair centres. The following table gives possible
causes and remedies for common problems.
PROBLEM
Tool will only reach 120bar in advance
mode, but higher in retract mode.
Tool advances when retract button is
pressed and vice versa.
Motor stalls before 700 bar is reached.
Motor runs slowly
OPERATING INSTRUCTIONS FOR HTWP21 SERIES
AIR DRIVEN TORQUE PUMPS
POSSIBLE CAUSE
Tool incorrectly connected. Swap hose
connections at tool.
Pendant signal hoses wrongly connected –
swap hoses at connections (11)
Low supply pressure or insufficient air flow.
Low supply pressure or insufficient air flow.
Page 4 of 8
Approved by:-
Matthew Hughes
TDS:-
1319
Date: 19/10/12