Dynabrade 52567 Safety, Operation And Maintenance Manual - Page 3
Browse online or download pdf Safety, Operation And Maintenance Manual for Sander Dynabrade 52567. Dynabrade 52567 9 pages. 1hp right-angle disc sander governor controlled
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
I
mportant: A preventative maintenance program is recommended whenever portable power tools are used. The program should include inspection of air supply
lines, air line pressure, proper lubrication and repair of tools. Refer to ANSI B186.1 for additional maintenance information.
• Use only genuine Dynabrade replacement parts to insure quality. To order replacement parts, specify Model#, Serial# and RPM of your air tool.
• It is strongly recommended that all Dynabrade rotary vane air tools be used with a Filter-Regulator-Lubricator to minimize the possibility of misuse due
to unclean air, wet air or insufficient lubrication. Dynabrade recommends the following: 10681 Air Filter-Regulator-Lubricator (FRL) – Provides accurate
air pressure regulation and two stage filtration of water contaminants. Operates 55 SCFM/1,558 LPM @ 90 PSIG with 1/2" NPT female ports.
• Lubricate wick system through the angle gear oil fitting with 2-3 plunges for every 8 hours of use, to achieve maximum gear life. Important: Use only the
recommended angle gear oil for the wick system. Do not contaminate the wick with any other oil or grease product (order 95848 Gear Oil and 95541 Gun).
• Dynabrade recommends one drop of air lube per minute for each 20 SCFM (example: if the tool specification states 40 SCFM, set the drip rate on the
filter-lubricator to 2 drops per minute). Dynabrade Air Lube (P/N 95842: 1 pt 473 ml) is recommended.
Routine Preventative Maintenance:
• Check free speed of right-angle sander using a tachometer. This governor controlled right-angle sander should be speed checked every 20 hours of use or
weekly, whichever occurs more frequently.
• DO NOT disassemble the governor for any reason. Reorder correct speed – governor assembly (See Assembly Breakdown) and recheck free speed of
tool with a tachometer.
• Inspect pad backing for excessive wear, nicks, cracks and cuts at the pad edges. Do not use pads that show excessive wear. Check pad backing for concentricity.
• Visually inspect abrasive discs for nicks, cuts, tears at the edges. Abrasive disc with a curved shape indicates improper storage. Do not use abrasives that show
these characteristics.
• Mineral spirits are recommended when cleaning the tool and parts. Do not clean tool or parts with any solvents or oils containing acids, esters, ketones,
chlorinated hydrocarbons or nitro carbons.
• DO NOT clean or maintain tools with chemicals that have a low flash point (example: WD-40
• A Motor Tune-Up Kit (P/N 96532) is available which includes high wear and medium wear motor parts.
• Air tool labels must be kept legible at all times, if not, reorder label(s) and replace. User is responsible for maintaining specification information i.e.: Model #,
S/N, and RPM. (See Assembly Breakdown)
• Blow air supply hose out prior to initial use.
• Visually inspect air hoses and fittings for frays, visible damage and signs of deterioration. Replace damaged or worn components.
• Refer to Dynabrade's Warning/Safety Operating Instructions Tag (Reorder No. 95903) for safety information.
After maintenance is performed on tool, add a few drops of Dynabrade Air Lube (P/N 95842) to the air line and start the tool a few times to lubricate air motor. Check
for excessive tool vibration.
Handling and Storage:
• Use of tool rests, hangers and/or balancers is recommended.
• Protect tool inlet from debris (see Notice below).
• DO NOT carry tool by air hose or near the tool throttle lever.
• Protect abrasive accessories from exposure to water, solvents, high humidity, freezing temperature and extreme temperature changes.
• Store abrasive discs prior to use at 30-50% relative humidity and 60-80˚ F (15-27˚ C) to reduce curling.
• Store accessories in protective racks or compartments to prevent damage.
Model
Motor
Tool
Sanding
Number
HP (W)
RPM
Disc Dia.
52560
1 (746)
12,000
52561
1 (746)
11,000
52562
1 (746)
9,000
52563
1 (746)
6,000
52564
1 (746)
9,000
52565
1 (746)
11,000
52566
1 (746)
12,000
52567
1 (746)
6,000
Additional Specifications: Air Inlet Thread 3/8" NPT • Hose I.D. Size 3/8" (10mm) • Air Flow Rate Based At Max HP. • Air Pressure 90 PSIG Max
All Dynabrade motors use the highest quality parts and metals available and are machined to exacting tolerances. The failure of quality pneumatic motors can most
often be traced to an unclean air supply or the lack of lubrication. Air pressure easily forces dirt or water contained in the air supply into motor bearings causing early
failure. It often scores the cylinder walls and the rotor blades resulting in limited efficiency and power. Our warranty obligation is contingent upon proper use of our tools
and cannot apply to equipment which has been subjected to misuse such as unclean air, wet air or a lack of lubrication during the use of this tool.
Following the reasonable assumption that any inherent defect which might prevail in a product will become apparent to the user within one year from the date of
purchase, all equipment of our manufacture is warranted against defects in workmanship and materials under normal use and service. We shall repair or replace at
our factory, any equipment or part thereof which shall, within one year after delivery to the original purchaser, indicate upon our examination to have been defective.
Our obligation is contingent upon proper use of Dynabrade tools in accordance with factory recommendations, instructions and safety practices. It shall not apply to
equipment which has been subject to misuse, negligence, accident or tampering in any way so as to affect its normal performance. Normally wearable parts such as
bearings, contact wheels, rotor blades, etc., are not covered under this warranty.
Buy parts on line at https://Dynashop.co.uk/ for all things Dynabrade
Maintenance Instructions
Machine Specifications
Sound
Air Flow Rate
Level
SCFM (LPM)
4"
78 dB(A)
40 (1,132)
4
1
/
"
79 dB(A)
41 (1,161)
2
5"
80 dB(A)
39 (1,104)
7"
82 dB(A)
40 (1,132)
N/A
80 dB(A)
39 (1,104)
N/A
79 dB(A)
41 (1,161)
N/A
78 dB(A)
40 (1,132)
N/A
82 dB(A)
40 (1,132)
One Year Warranty
®
).
Air Pressure
Spindle
PSIG (Bars)
Thread
90 (6.2)
3/8"- 24 Male
90 (6.2)
5/8"-11 Male
90 (6.2)
5/8"-11 Male
90 (6.2)
5/8"-11 Male
90 (6.2)
M14 x 2 Male
90 (6.2)
M14 x 2 Male
90 (6.2)
M14 x 2 Male
90 (6.2)
M14 x 2 Male
Notice
3
Weight
Length
Height
Pound (kg)
Inch (mm)
Inch (mm)
4.0 (1.8)
11-11/16 (296)
4-1/4 (108)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)
4.0 (1.8)
11-11/16 (296)
3-3/4 (93)