Gaggenau AH 600 Operating And Assembly Instructions Manual - Page 20
Browse online or download pdf Operating And Assembly Instructions Manual for Ventilation Hood Gaggenau AH 600. Gaggenau AH 600 20 pages. Extractor hood
Fig. 25
Fig. 26
Fig. 27
03.6028.27ind01
en 10.00 SK
– Screw together the air guidance housing and
screw it onto the two retaining brackets (Fig. 25).
– Establish the pipe connection between the air
connection piece and the air guidance housing.
– Establish the electrical connection.
– Stick the included sealing strips (8 strips) around
the air slots on the top chimney paneling.
– Remove the protective foil from the chimney
paneling.
Note: Avoid damaging the sensitive stainless steel
surfaces.
– Join the chimney shoe with the chimney base
using the 6 screws (3.5 x 9.5 mm) (Fig. 26).
– Fit the top of the chimney into the base. Make
sure that the fastening holes on the side are at the
top.
– Secure the top duct unit with 2 screws on the
ceiling holder.
– Pull the shoe down into its final position
(Fig. 27)
Note: Avoid scratches when fitting the elements
into one another by placing the assembly template,
for example, over the edge of the bottom chimney
paneling to protect it.
– Make sure that an activated charcoal filter is
installed (see page 10).
– Reinsert the grease filters.
– Again screw in the two black plates on the left
and right of the chimney.
– Place the glass plates on the black plates.
19