Gaggenau AH 600-190 Operating And Assembly Instructions Manual - Page 16
Browse online or download pdf Operating And Assembly Instructions Manual for Ventilation Hood Gaggenau AH 600-190. Gaggenau AH 600-190 18 pages. Gaggenau ventilation hood user manual
Also for Gaggenau AH 600-190: Operating And Assembly Instructions Manual (19 pages)
Fig. 20
Fig. 21
Fig. 22
– Secure the hood to the wall using the 4 screws b
with shims c (Fig. 20).
– Establish the pipe connection.
– Establish the electrical connection.
– Extract the protective file from the chimney
paneling.
Note: Avoid damaging the sensitive stainless steel
surfaces.
– Join the chimney shoe with the chimney base
using the 6 screws (3.5 x 9.5 mm) (Fig. 21).
– Fit the top of the chimney into the base. Make
sure that the fastening holes on the side are at the
top.
– Secure the top duct unit with 2 screws on the
ceiling holder.
– Pull the shoe down into its final position
(Fig. 22).
Note: Avoid scratches when fitting the elements
into one another by placing the assembly template,
for example, over the edge of the bottom chimney
paneling to protect it.
– Reinsert the grease filters.
– Again screw in the two black plates on the left
and right of the chimney.
– Place the glass plates on the black plates.
15