Section 6 – Periodic Maintenance
Periodic maintenance is essential to the safe and proper operation of your equipment. Contact Precision® Extraction Solutions directly for
replacement components. Obtaining replacement components from a third party voids your warranty and invalidates the engineering peer
review of the equipment.
Use ONLY approved, food-safe cleaners, solvents, and sanitizers. Conduct the cleaning activities in an area with adequate ventilation or under
an explosion-proof fume hood.
The wear on the individual machine components varies greatly depending on the amount of usage in a timeframe. Always replace worn
components immediately. It is EXTREMELY IMPORTANT to inspect all nuts, bolts, and gaskets before every use of the system. If there is any
question as to the integrity of any given component, replace it immediately.
Inspect all seals, nuts, bolts, and gaskets. If damaged, replace.
Inspect sanitary clamp bolts/nuts.
Inspect gaskets for visible signs of wear. Retighten if necessary.
Perform a complete system cleaning.
Ensure pressure relief valves perform as intended. Replace as needed.
Inspect the ball valves. Replace as needed.
Inspect the quick connects. Replace if damaged.
Inspect the sight glass for signs of damage or wear. Replace as needed.
Clean the surface of the sight glass using a standard commercial cleaner and a soft cloth.
Inspect the high-pressure clamp. Ensure the two segments have a gap between them and the inside
diameter is not touching the outside diameter if the hub.
Check the clamp locking nuts are tight to prevent the nuts from loosening.
Visually check the pressure gauge display and function for damage at regular intervals in line with the
operating conditions and ambient conditions.
Clean the pressure gauge with a non-aggressive cleaning agent. Close the ventilation valve in
accordance with the protection category of the device.
Actions
Model HDU Operational Manual – For Hazardous Environments
Precision® Extraction Solutions
©2022 PX2 Holdings, LLC. All rights reserved. Rev. 04/24/23
Model HDU Operational Manual – For Hazardous Environments
Frequency
Before every use
Every use or at first visible sign
of wear
Every use or at first visible sign
of wear
Monthly
Monthly
Annually
Annually
Periodically
Periodically
Periodically
Periodically
Periodically
Periodically
10