4. Connection of the panels (see Fig. 1)
The supply cables can be interconnected (looped) directly in the terminals of the panels. A shutoff device, in which
the distance be-tween disconnected contacts is at least 3.5 mm for all poles, must be built into the distribution
system. Regulation is provided via room thermostats with time switching (offered by CEILHIT) which switch power
relays or contactors. For larger buildings, a microprocessor control system is suitable. In special cases, regulation
needs to be considered depending on the situation (zonal temperature mainte-nance, etc.).
Panels S + 30-36 can be regulated via symmetrical shutoff of the segments (level 1 – central segment, level 2 –
both edge segments, level 3 – all segments switched off.
Any alterations made to the factory connection in the terminal will result in the destruction of the heating
lamellas. In order to comply with the warranty conditions, the customer may only make alterations in the
part of the terminal which is used for the connection of the supply cable.
Panels S+ 09 - 12
DO NOT TAMPER WITH
THE CONNECTION
DO NOT TAMPER WITH THE CONNECTION
5. Maintenance
This is limited to cleaning the panel by dusting it or wiping it with a moist cloth and detergent. The radiant surface
is not cleaned.
Dust deposits and dampness on the surface of the product lead to the corrosion of components. Remove the
dust and dirt, which absorbs dampness, at least once a year (at least twice a year in environments with
higher humidity, mineral substances in the atmos-phere or excessive dust).
Panel S+ 18 – 24 and 06 – 08
DO NOT TAMPER WITH
THE CONNECTION
Panels S+ 30 - 36
DO NOT TAMPER WITH THE CONNECTION
DO NOT TAMPER WITH
THE CONNECTION