W
g ltrltftO
4.0
DY 4000
Manual & Automatic Close Timers
Setting the Manual & Automatic Glose Timers
The Dynalogix ll has two automatic close timers. The first timer, MG/PB timer,
will count down after a activation is installed on terminal number 2 (most
commonly used for pull cords or pushbuttons). MC/PB timer also can be
turned on or off, making it manual operation or automatic operation simply by
assigning a countdown value to the timer. The second timer, AC/Loop timer,
will count down after a activation is installed on terminal 4 (most commonly
used are motion sensors and loops). lf this timer is set to zero, the door will
come down after door reaches upper limit.
4.1
Setting MC/PB Timer
'1. Press and release MC/PB Timer button on the Dynalogix ll controller.
The display will change to: MC Delay_Time=##. See figure 4.1-1.
MC/PB
Timer
Figure 4.1-1: MC/PB Timer
2. Use the Up and Down arrow buttons to change the countdown time to the
desired duration. The Dynalogix llwill automatically save any changes that
are made. See fioure 4.1-2.
lncrease
Setting
Decrease
Setting
Figure 4.1-2: Raise/Lower Manual Timers