Please Note: The impulses should range
i
between 5,000 to 15,000. If speed calibration
results are outside this range, perform a new
speed calibration operation.
Please Note: Great Plains does not recommend
i
manual adjustment of the value in the impulse
field. Shown below.
Please Note: You may complete a new
i
speed calibration operation without saving
the previous calibration results. Tap
key to complete a new calibration.

Troubleshooting

An unsuccessful speed calibration often times occurs
because:
The calibration operation was canceled when the
soft key was tapped.
The intended field speed was not maintained during
the 300 ft. (91.5 m) speed calibration operation. The
number of impulses shown should range between
5,000 to 15,000. If your speed calibration results are
outside of the range, preform a new speed calibration
operation.
The 300 ft. (91.5 m) measurement between the two
field markers was inaccurate.
The radar sensor is improperly mounted. Make
adjustments based on these recommendations:
Great Plains | 195-835QS | 03/25/2022
 Mounting Angle: 35° forward facing.
 Mounting Height: 12 to 48 inches above the
ground or above the crop; average height is 24
inches.
 Product Database
This section will provide instruction on how to manage
the Product Database.
Product Profile Configuration
To edit product profile configuration:
1. On the Home menu, tap
soft
2. On the Machine Settings menu, tap
3. On the Configuration menu, tap
BD7600 Quick Start Guide
soft key.
soft key.
soft key.