ADEMCO LYNXR24 Quick Start Manual - Page 4
Browse online or download pdf Quick Start Manual for Security System ADEMCO LYNXR24. ADEMCO LYNXR24 8 pages.
Also for ADEMCO LYNXR24: Quick Start Manual (8 pages)
Step
Enhanced Sequential Mode - Press *83, then follow the prompts as follows:
3.
a.
Zone Number
%
entered. The system will announce the Voice Descriptor for the selected zone number, if it is
programmed.
Press [*] to continue. Starting with this zone, the system will search for the first transmitter,
which has all of the following attributes pre-programmed in Zone Programming.
1)
2)
3)
4)
Notes: 1. If the first zone number entered does not have one or more of the above attributes, the
b.
zz
Enroll Mode - If " L " is displayed, the serial number for this transmitter has already been entered,
%
however, it may still be confirmed, viewed or deleted.
1)
2)
% 0'
Note:
3)
Note:
4)
Note:
5)
6)
b zz
c.
Serial Number
transmission or manually. If using RF Learning proceed to c. 1). If using the manual mode skip to
c. 2).
1)
Note:
Enter 2-digit zone number of the first transmitter to have its serial number
The correct input type selected in *56 (RF, UR, or BR programmed)
The correct loop number selected in *56
No serial number programmed
Zone type
system will search its database for the first zone that does, and will display it at the
ENROLL SERIAL NUMBER prompt (1b).
2. Pressing 00 exits mode, upon which the prompt "83" blinks, indicating the mode is
inactive.
If the transmitter's serial number has not been previously entered, enter the enroll serial
number mode now by pressing "1", or copy the last serial number that was entered by
pressing "2".
If the transmitter's serial number has been previously entered, it may be viewed by pressing
"3" or deleted by pressing "9".
If view is selected; each digit will be re-displayed, and the keypad will beep once for digits 1-
6, and three times for the last digit.
Once the serial number has been entered the system will return to the (1A) prompt and " L " will
be displayed.
This point can be faulted and restored and the panel will listen for the transmission.
The serial number/loop number combination that was entered can be confirmed by faulting
and restoring the zone being entered. If the panel receives a transmission that matches the
serial number and loop number entered, the keypad will beep three times, and "C" will be
displayed. This indicates that the serial number transmission has been confirmed to match.
No further transmissions will be received.
When confirming a 4-button key, it assumed that all loops are used and only the serial
number is confirmed. Pressing any key will allow a confirm. Two beeps indicate that the
template has been accepted. A single long beep indicates illegal entries, or duplicate serial
number/loop entry.
When the last zone has been entered, the display will remain on that zone. To exit this mode
and return to data field program mode, press 00 at the ZONE NUMBER prompt
Once all zones have been programmed, test each zone using the system's Test mode. Do not
use the Transmitter ID Sniffer mode for this, since it will only check for transmission of one
zone on a particular transmitter, and not the zones assigned to each additional loop.
- This prompt can be used to enroll the transmitter serial number via RF
RF Learning - Two (2) transmissions (two key depressions at least five second apart) will be
required for BR type or four (4) transmissions (fault, restore and fault, restore) for UR or RF
type. BR type devices can be enrolled only by transmission from BR devices. Likewise, UR
and RF devices can only be enrolled by transmission from a UR or RF device.
If the learned serial number has a different loop number than that entered in *56 the system
will announce the Voice Descriptor, if it is programmed, followed by two beeps and will return
to Prompt (1A) and "L" will be displayed.
If the loop number captured by RF transmission and that entered in *56 mode match, the
system will announce the Voice Descriptor, if it is programmed, followed by three beeps and
return to Prompt (1A) and "LC" will be displayed. No additional transmissions are needed for
confirmation.
BR type devices can be enrolled only by transmission from BR devices. Likewise, UR and RF
devices can only be enrolled by transmission from a UR or RF device.
Action
-4-