ADEMCO Security System VISTA-10SE Programming Manual - Page 10

Browse online or download pdf Programming Manual for Security System ADEMCO Security System VISTA-10SE. ADEMCO Security System VISTA-10SE 16 pages.

ADEMCO Security System VISTA-10SE Programming Manual
OUTPUT RELAYS WORKSHEET FOR FIELDS 80 and 81.
80 OUTPUT RELAYS – This is an Interactive Menu mode. Fill in the required data on the worksheet below and follow the
programming procedure in the installation manual as you enter the data in response to the displays and prompts that
appear in sequence.
Notes: 1. For Relays, field 25 must be programmed for a 4204 relay module (enter 3).
2. Tampers of contacts or an expansion unit cannot be used to operate relays.
RELAY
OUTPUT
ACTION
RELAY
(A)
01
02
03
04
Where:
A = DEVICE ACTION
EV = EVENT
ZL = ZONE LIST
ZT = ZONE TYPE/SYSTEM OPERATION
Choices for Zone Types are:
00 = Not Used
01 = Entry/Exit #1
03 = Perimeter
04 = Interior Follower
05 = Trouble Day/Alarm Night
Choices for System Operation are:
20 = Arming–STAY
21 = Arming–AWAY
22 = Disarming (Code + OFF)
31 = End of Exit Time
32 = Start of Entry Time
33 = Any Burglary Alarm
34 = Code + # + 7 Key Entry
35 = Code + # + 8 Key Entry
81
ZONE LISTS FOR OUTPUT RELAYS Record desired zone numbers. More or fewer boxes than shown may be
needed, since any list may include any or all of system's zone numbers.
Zone List 01: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 02: Started or stopped by zone numbers (enter 00 to end entries).
,
Zone List 03: Started or stopped by zone numbers (enter 00 to end entries).
,
Applicable only if 4204 relays are to be used.
S T A R T
either or both
ZONE
EVENT
LIST
(EV)
(ZL)
0 = No response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off.
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble.
1, 2, or 3 (from Field 81) or 0 = Not used.
START ZONE LIST:
STOP RESTORE of ZONE LIST: Upon restore of ALL zones on this list, device action
** Or at Disarming, whichever occurs first.
,
,
,
,
,
,
,
,
,
ZONE TYPE
RESTORE of
SYSTEM OPERATION
ZONE LIST
(ZT)
Upon alarm, fault, or trouble of ANY zone on this list, relay action
will START.
will STOP. It need not be same list as used for START.
06 = 24-Hr Silent
07 = 24-Hr Audible
08 = 24-Hr Aux
09 = Fire
10 = Interior w/ Delay
36 = At Bell Timeout**
38 = Chime
39 = Any Fire Alarm
40 = Bypassing
41 = AC Power Failure
42 = System Battery Low
58 = Duress
,
,
,
,
,
,
– 10 –
S T O P
either or both
ZONE TYPE/
SYSTEM OPERATION
(ZL)
(ZT)
Note: Any zone in "ZT" going into
alarm, fault, or trouble will
actuate relay.
Any zone of that type that
restores will stop relay action.
,
,
,
,
,
,
,
,
,
...etc.
...etc.
...etc.