STEP
STEP
4
4
Remove  the  4  screws  holding  the  chamber  block 
and the casing block. 
(4 screws on each side)
STEP
STEP
5
5
Remove  1  U-lock  nuts  from  one  side  holding  the 
diaphragm mounting block to the rod. 
●Use the nut driver to loosen (or tighten) the U-lock nut.
STEP
STEP
6
6
Remove one of the diaphragm mounting blocks from 
the  actuating  rod  and  pull  out  the  other  diaphragm 
mounting block with the rod. After that, separate the 
diaphragm mounting block and the rod. 
●When pulling out the rod, be sure not to catch the rod 
projection on the lever of the SP switch. 
●If the pump stops automatically, the safety pin must be broken to prevent any 
further  damage  to  the  pump.  Be  sure  all  broken  pieces  are  removed  from  the 
unit.(See Step 15)
STEP
STEP

REPLACING THE DIAPHRAGM

7
7
In case of replacing the whole diaphragm mounting 
STEP 12
block, move straight to 
Remove the diaphragm ring from the diaphragm, 
and  then,  detach  the  diaphragm  from  the 
diaphragm base.
REPLACING THE CHAMBER BLOCK
3