HIBLOW hp-200 Instruction Manual - Page 11

Browse online or download pdf Instruction Manual for Air Compressor HIBLOW hp-200. HIBLOW hp-200 17 pages. Air pumps
Also for HIBLOW hp-200: Instruction Manual (13 pages), Manual (8 pages)

HIBLOW hp-200 Instruction Manual
Fig. 17
Casing A
(10) After the valves have been inserted into the casing A, cut off their respective pulling ends using
scissors or nippers. Secure casing B and valve chamber packing to casing A by the five screws.
This completes the valve replacement procedure, and use this assembly as a new casing block.
Fig. 19
Cut section
• When replacing the diaphragms, be sure to change the valves with new ones, too.
• When reinstalling the valves, take care to make sure that they are correctly fit in the exhaust and
intake sides. Wrong orientation may result not only in performance decreasing but in a failure of
the pump.
• Tighten each of five screws gradually and uniformly till they are firmly fastened.
If they are not tightened uniformly, it may cause leakage of air or failure of pump.
Valve
Cut section
CAUTION
Fig. 18
Exhaust side
Fig. 20
Intake side
(Fig. 19 and 20)
11