Dynacord DMM 4650 Technical Information - Page 14
Browse online or download pdf Technical Information for Computer Hardware Dynacord DMM 4650. Dynacord DMM 4650 19 pages. Signal processor
Example 3
Intention:
You want to trigger the pre-programmed 3-tone gong signal (factory-preset G21) by an external key.
The functioning of the 4-tone gong signal has to be maintained.
Summary
1. To include the reproduction of the 3-tone gong signal in the existing configuration, you have to
program a suitable control sequence (e. g. S05). The sequence is also about to trigger an external
control-lamp for the time, the gong signal gets reproduced. This example utilizes the identical relay
contact 4 of the port A (=A4) that is already in use for the 4-tone signal.
2. The unused input of the pre-gong signal (e.g. B4) has been connected to the start-key (page 30). It
has to be programmed in the trigger menu to activate the above sequence (S05).
Step By Step Programming
Enter the password for the user level 3 on the display,
using the four cursor keys (page 10) and confirm your
action with the "ok"-button.
If you have entered the correct password,
the display briefly shows this message and
then returns to the main menu.
Creating a procedure, the 3-tone gong signal G21 has to be included into a sequence (page 23). The
sequence-preset S 25 is chosen as the root-preset for further programming (page 39).
After pressing the indicated cursor key five times, the
sequence menu appears on the display. Confirm your
selection by pressing the "ok"-button.
Pressing the soft key "ok" once again shows a menu that
lets you select a sequence-preset.
The blinking cursor is positioned at the "0" in the
display's bottom line.
Press the indicated cursor key repeatedly until "S 25" is
selected. Press the soft key "yes" to load the sequence
preset S 25 (root-sequence).
Since the procedure has to be changed in accordance to
the new requirements, you have to select its listing by
pressing the "ok" key.
The first step (step 1) of the S 25 listing is displayed,
which stays unchanged (relay contact A1 can be utilized
to turn the system's power on).
Pressing the indicated cursor key displays step 2 which
stays unchanged (release-input A1 of the electro
acoustic system ready?).
Pressing the indicated cursor key displays step 3 which
stays unchanged (relay contact B4 for music off).
Dynacord DMM4650
Userlevel 3
Programming The Control Sequence
Ù
password?
Ø
×
****
Ú
Main-Menu
System-Setup
Ù
Main-Menu
Ø
×
Sequence
5x
Ú
Sequence
Sequ load
S20 'stop all' n
Ù
5x
Sequ load
Ø
×
S25 'Vierklng' n
Ú
Sequence
steplist
steplist
1:OutA.1 set
Ù
steplist
Ø
×
2:wt InA.1 H
Ú
Ù
steplist
Ø
×
3:OutB.4 clr
Ú
ok
ok
ok
load
ok
y
y
ok
d
i
d
i
d
i