HIBLOW hp-80 Quick Start Manual - Page 6

Browse online or download pdf Quick Start Manual for Air Compressor HIBLOW hp-80. HIBLOW hp-80 7 pages.
Also for HIBLOW hp-80: Instruction Manual (13 pages)

HIBLOW hp-80 Quick Start Manual
HP- 60/80
! 
●Be sure to unplug the pump unit.
●When  performing  replacement  work,  the  pump  body  may  still  be  hot  and  you  could
get burned. So please wait until the pump has cooled before handling.
●Be  sure  to  remove  the  chamber  block  and  the  actuating  rod  before  replacing  the
electromagnet.
●It  is  better  to  let  an  experienced  technician  handle  the  soldering  process.  Take
precautions against getting burned.
STEP
STEP
REMOVAL OF ELECTROMAGNET
1
1
Cut  the  wire  from  terminals  on  the  electromag-
nets with nippers.
●It is recommended that you make a note of the wiring.
STEP
STEP
2
2
Loosen the screw, fixing SP switch and remove it . 
(There  are  hexagonal  nuts  at  SP  switch  side.  Be 
sure not to lose them as they fall inside the unit.)
STEP
STEP
3
3
Remove the hexagonal nuts by the nut driver. 
(7mm wrench) 
Pull out the electromagnets from the pump body.
6
AUTION
Goodies Wastewater Supplies
Phone: 1300 282 181  Fax: 1300 282 989
PO Box 1524, Oxenford QLD 4210  35 Scenic Cr, Coomera QLD 4209
Email: [email protected]  Web: www.goodies.net.au