GAI-Tronics 709-901 User Manual - Page 11

Browse online or download pdf User Manual for Amplifier GAI-Tronics 709-901. GAI-Tronics 709-901 16 pages. Smartseries handset/speaker amplifier

GAI-Tronics 709-901 User Manual
M
709-901 S
S
ODEL
MART
ERIES

Internal Adjustments

CAUTION
To reduce the risk of ignition of hazardous atmospheres, disconnect the equipment from the supply
circuit before making any adjustments to the amplifier's handset level.
Although they typically require no adjustments, the following volume levels can be set internally:

Sidetone Volume and Handset Receiver Volume

To make an adjustment it is necessary to remove the assembly from its enclosure and make a temporary
connection between the assembly and the enclosure. Refer to Figure 2 for the reference numbers and
locations of the adjustment controls. Turn a control clockwise to increase the volume or threshold; turn it
counterclockwise to decrease the volume or threshold. Use a small flat-blade screwdriver with an
insulated shaft to make adjustments.
To access the controls, perform the following steps:
1. Loosen the four screws that secure the front panel.
2. Remove the assembly from the enclosure. If the enclosure is equipped with an optional EOL Module
or SmartSeries station RTU, be careful to not disconnect the ribbon cable on J2 of the Speaker
Amp/Power Supply PCBA.
3. Connect the assembly to the enclosure using a Model 10440-002 Maintenance Cable between P1 on
the assembly and J1 on the enclosure.
4. Locate and adjust the control on the appropriate PCBA.
5. When you are finished with the adjustment:
a) Disconnect the Model 10440-002 Maintenance Cable.
b) Insert the assembly into the enclosure.
c) Tighten the four screws.
Handset Receiver Volume
Use the control labeled RCVR VOL (Ref. 7, on the Handset/FSK/P PCBA) to adjust to the desired level
the handset receiver volume for voice signals from a party line.
Sidetone Volume
The control labeled SIDETONE (Ref. 4, on the Handset/FSK/P PCBA) adjusts the handset/headset
sidetone.
f:\standard ioms - current release\42004 instr. manuals\42004-699l2d.doc
10/13
H
/S
A
ANDSET
PEAKER
MPLIFIER
P
. 42004-699L2D
UB
10 of 14
P
AGE