Automatic Technology Megacode Tricode 128 Manual - Page 12
Browse online or download pdf Manual for Receiver Automatic Technology Megacode Tricode 128. Automatic Technology Megacode Tricode 128 20 pages. Multi-frequency four channel receiver
9. Appendix
OPERATIONAL BUTTONS:
1. Press PREV/NEXT buttons move to Left/Right.
2. Press OPEN/CLOSE buttons to change setting.
3. Press SET button to save changes.
4. Press STOP to return to MENU without saving changes.
Parameter
Menu 1 - Code Transmitter
STORING TRANSMITTERS
Menu 2 - Output One Setup
OUTPUT PULSE TIME: This parameter sets the duration of the output pulse
time. The output pulse time is used only for pulse functions.
PULSE TIME UNITS: This parameter sets the units used for the ouput time
settings. The options are Sec, Min or Hrs.
FLASH ON TIME: A flash on output is created by repeatedly turning the
output on and off. The Flash On time sets the duration of the on phase. For
a steady output state which does not flash, set the Flash on Time = 0.0s.
FLASH OFF TIME: A flash off output is created by repeatedly turning the
output on and off. The Flash Off time sets the duration of the off phase. The
Flash Off Time is not used for steady state outputs.
COMPLETE FLASH SEQUENCE: Turning this parameter on will allow the
flash cycle to complete if the output is turned off during the flash cycle.
OUTPUT ONE INVERTED: This parameter allows its operation to be
changed to N/C.
TRIGGER ONE INPUT: Output One can also be controlled via independent
Trigger One input. The trigger input can be programmed to activate its
output similar to a transmitter button.
TRIGGER ONE INPUT CONTACT: This parameter allows its operation to be
changed to N/C.
DISABLE ONE INPUT CONTACT: This input can be used to disable the
output in software regardless of the state of the transmitters, wired inputs or
time clock. The parameter allows it operation to be changed to N/C.
Menu 3 - Output Two Setup
OUTPUT PULSE TIME
PULSE TIME UNITS: This parameter sets the units used for the ouput time
settings. The options are Sec, Min or Hrs.
FLASH ON TIME: A flash on output is created by repeatedly turning the
output on and off. The Flash On time sets the duration of the on phase. For
a steady output state which does not flash, set the Flash on Time = 0.0s
FLASH OFF TIME: A flash off output is created by repeatedly turning the
output on and off. The Flash Off time sets the duration of the off phase. The
Flash Off Time is not used for steady state outputs.
COMPLETE FLASH SEQUENCE: Turning this parameter on will allow the
flash cycle to complete if the output is turned off during the flash cycle
OUTPUT TWO INVERTED: This parameter allows its operation to be
changed to N/C.
TRIGGER TWO INPUT: Output Two can also be controlled via independent
Trigger Two input. The trigger input can be programmed to activate its
output similar to a transmitter button.
TRIGGER TWO INPUT CONTACT: This parameter allows its operation to be
changed to N/C.
DISABLE TWO INPUT CONTACT: This input can be used to disable the
output in software regardless of the state of the transmitters, wired inputs or
time clock. The parameter allows it operation to be changed to N/C.
12
MegaCode
Receiver Installation Instructions
®
A - Receiver Menu Structure
NOTE: The System will automatically return to the main screen after
30 secs if a menu screen is displayed and no buttons are pressed.
Min
0.0
0.1
Sec
0.0
0.1
Off
Off
Off
Off
Off
0.1
Sec
0.0
0.1
Off
Off
Off
Off
Off
Max
Default
Unit
511
99.9
1.0
Sec.
Hrs
Sec
Sec, Min,
Hrs
999.9
Off
Sec
999.9
0.5
Sec
On
Off
On
Off
On
Off
On
Off
On
Off
99.9
1.0
Sec.
Hrs
Sec
Sec, Min,
Hrs
999.9
Off
Sec
999.9
0.5
Sec
On
Off
On
Off
On
Off
On
Off
On
Off
Menu
Section
1
4.1
2.1
Appendix B
2.2
Appendix B
2.3
Appendix B
2.4
Appendix B
2.5
Appendix B
2.6
Appendix B
2.7
Appendix B
2.8
Appendix B
2.9
Appendix B
3.1
Appendix B
3.2
Appendix B
3.3
Appendix B
3.4
Appendix B
3.5
Appendix B
3.6
Appendix B
3.7
Appendix B
3.8
Appendix B
3.9
Appendix B