AirCycler g2-k Training Manual - Page 11

Browse online or download pdf Training Manual for Thermostat AirCycler g2-k. AirCycler g2-k 20 pages.
Also for AirCycler g2-k: Installation & User Manual (11 pages), Installation Testing Manual (2 pages), Installation Testing Manual (2 pages)

AirCycler g2-k Training Manual
2.0 AIRCYCLER® G2 OPERATION
2.1 READING THE AIRCYCLER® G2
OA
Damper Open
EXH
Exhaust Fan On
FAN
Central Fan On
ON
G2 Operation On (Forcing Central Fan On)
%
Percent Ventilate Complete for Hour
CFM
Air Flow Cubic Feet Per Minute Values
SET
Setup Mode
REQ
Required CFM Setting
TIME
Time Setting Mode
HR
Hour
MIN
Minutes
AM
Time - AM
PM
Time - PM

2.2 NORMAL OPERATION DISPLAY

Normal display will show the percentage of the current
ventilation cycle (hour) that is complete.
If the central fan is running from a thermostat call, the
FAN icon will show.
If the AirCycler® g2 has forced on the central fan, the
FAN and ON icons will show.
If the exhaust (bath) fan is on, the EXH icon will show.
If the outside fresh air damper is open the OA icon will show.
If the EXH fan is running its set delay time after the FanConnect™ has been turned off, the delay time countdown as
well as the MIN and EXH icons will show.

2.3 ENTERING SETUP MODE

Once wiring is complete, place the controller on the base. All icons will be illuminated for 3 seconds.
Press the UP arrow within 3 seconds of power up to enter Calculated Flow Setup
Press the DOWN arrow within 3 seconds of power up to enter Calculated Time Setup
If a set up method was not selected within 3 seconds, remove controller from base and replace to re-enter setup mode.
G2 DISPLAY KEY
FUNCTIONS APPLY WHEN ICONS ARE
ACTIVE/ILLUMINATED
THE DAMPER
THE EXHAUST
FAN IS ON
THE THERMOSTAT
HAS TURNED ON
THE CENTRAL FAN
THE AIRCYCLER® G2
HAS FORCED THE FAN
11
IS OPEN
PERCENTAGE OF
VENTILATION COMPLETE
AC DOC 8.5
REV 7/2020
LCD DISPLAY