GAI-Tronics 370-901 Manual - Page 6

Browse online or download pdf Manual for Recording Equipment GAI-Tronics 370-901. GAI-Tronics 370-901 19 pages. Sp2 to page/party bridge

GAI-Tronics 370-901 Manual
Model 370-901 SP2 to Page/Party
Ethernet—TB1
Terminate the Ethernet connection
at terminal block TB1.
1. Pull a Category 5 or better
Ethernet cable through the
conduit and into the enclosure.
2. Install ferrules onto the wire
ends.
3. Connect the Ethernet cable to
the 8-position pluggable
terminal block TB1 (see
Figure 4 and Table 1).
4. Connect the pluggable
terminal block to terminal
block receptacle TB1.
P:\Standard IOMs - Current Release\42004 Instr. Manuals\42004-525A.docx
08/18
®
Bridge
Figure 4. Main PCBA
Table 1. Ethernet Connector Wiring—TB1
1000Base-
100Base-
T Signal
TX Signal
(Label)
(Label)
DA+
DA−
DB+
DB−
DC+
DC−
DD+
DD−
Wire
Color
TX+
Orange Stripe
TX−
Solid Orange
Green Stripe
RX+
RX−
Solid Green
Solid Blue
Blue Stripe
Brown Stripe
Solid Brown
Pub. 42004-525A
Page 4 of 16
Wire Color
Designator
o
O
g
G
B
b
br
BR