4. Assemble the Airinx back together and hand
tight the top screw.
5. Remove the factory Airflow meter off from the
air cleaner box and install the Airflow mete to
the provided air flow meter adapter. Install the
Airinx and the adapter to suction Pipe S-1.
* The O-ring on the Airflow meter will be reused.
Apply some grease on the O-ring on the Airflow
meter, and make sure not to damage when
installing.
(Parts Used #14, 17, 38, 42, 43, 62)
6. Secure the Airinx with the provided bracket and
connect the Airflow meter connector.
7. Connect the air hose from the Metering Oil
Pump to suction pipe S-1.
Do not mistake this for the Jet Air Fuel Mixing hose.
8. Connect the Engine by pass hose on the Oil
filler pipe to the suction pipe S-1
Do not mistake this for the Jet Air Fuel Mixing hose.
3-7 Air Pump and Exhaust Installation
1. Install the provided Air Pump Hose to the factory AIR control valve and install the valve
back to the original location. And route the Air Pump Hose over the turbocharger.
*Use the factory gasket and bolts.
(Parts Used #18)
(Parts Used #31)
(Parts Used #31)
FLOW
(Parts Used #20)
Airflow
Sensor
Sensor
Attachment