HID RP10MA Installation Manual

Browse online or download pdf Installation Manual for Card Reader HID RP10MA. HID RP10MA 2 pages. 13.56 mhz contactless.
Also for HID RP10MA: Installation Manual (9 pages), Installation Manual (2 pages), Installation Manual (14 pages)

HID RP10MA Installation Manual
INSTALLATION GUIDE
iCLASS SE® / multiCLASS SE®
13.56 MHz Contactless
R10E, RP10E, R15E, RP15E, R40E, RP40E, RK40E, RPK40E
R10MA, RP10MA, RP15MA, R40MA, RP40MA, RPK40MA
www.hidglobal.com/PLT-03687
Scan the QR code or visit the link to see
ƒ
the multi-language electronic version of
this document.
Lisez le code QR ou suivez le lien pour
ƒ
consulter la version française de ce
document.
Escanee el código QR o visite el vínculo
ƒ
para consultar la versión en Español de
este documento.
Scannen Sie den QR-Code oder öffnen
ƒ
Sie den Link für die deutsche Version
dieses Dokuments.
Faça a leitura do código QR ou acesse
ƒ
o link da versão em português deste
documento.
Supplied parts
iCLASS SE/multiCLASSS SE Reader (1)
ƒ
Installation Guide (1)
ƒ
0.138-20 x 1.5" screws (2) – for installing the
ƒ
reader directly to a wall (no junction box)
0.138-32 x 0.375" screws (3) – for Imperial
ƒ
(US) junction box installation (2) and
attaching the reader to the back plate (1)
Recommended parts (not supplied)
Cable, 5-9 conductor (Wiegand or
ƒ
Clock-and-Data), 4 conductor Twisted
Pair Over-All Shield and UL approved,
Belden3107A or equivalent (OSDP)
Certified DC power supply
ƒ
Metal or plastic junction box
ƒ
ƒ
Security tool HID 04-0001-03 (for
anti-tamper screw)
© 2014 - 2019 HID Global Corporation/ASSA ABLOY AB. All rights
reserved. HID, the HID Brick logo, the Chain Design, iCLASS SE,
and multiCLASS SE are trademarks or registered trademarks of
HID Global, ASSA ABLOY AB, or its affiliate(s) in the US and other
countries and may not be used without permission. All other
trademarks, service marks, and product or service names are
trademarks or registered trademarks of their respective owners.
Optional features
Open Collector Output - Controls an external device (5 VDC) operating in Host Mode only. Sink –
40mA / Source – 1mA.
Optical Tamper (enabled by default on most readers) – A configuration card may be necessary
to activate the Optical Tamper. Once activated, when the mounting plate is removed, the optical
tamper will sink to ground from its default 5VDC. Contact HID Technical Support for Optical Tamper
options.
Configuration Cards – With the use of purchasable configuration cards, the reader can be modified
to meet the specific requirements of an installation. Configuration options include; audio visual, CSN
outputs and keypad outputs (keypad models only). Contact HID Technical Support for part number
assistance to order a configuration card, if necessary.
Hold Input – when asserted, this line either buffers a card (default) or disables a card read until
released, as configured.
1
Mount the backplate
ATTENTION
Observe precautions for handling
ELECTROSTATIC SENSITIVE DEVICES
1
2
For Imperial (US):
Use supplied 0.138-32 x 0.375" screws
For Metric (EU etc):
Use supplied M3.5 x 12mm screws
hi dg l ob a l .com
PLT-01579, Rev. A.6
Scansiona il codice QR o visita il
ƒ
link della versione Italiana di questo
documento.
Отсканируйте QR-код или пройдите по
ƒ
ссылке, чтобы получить версию этого
документа на русском языке.
ƒ ƒ 扫描ƒQRƒ码或访问此ƒ文档的中文版本的链接。
ƒ ƒ この文書の日本語版を表示するには、 QRƒコー
ドをスキャンするか、 リンクをƒクリ ックします。
ƒ ƒ QRƒ코드를 스캔하거나 링크를 방문하면 이ƒ
문서의 한국어 버전을 볼 수 있습니다.
M3.5 x 12mm screws (2) – for Metric (EU etc)
ƒ
junction box installation
0.138-32 x 0.375" security screw (1) –
ƒ
alternative security screw for attaching the
reader to the back plate
7-pin Terminal connectors (2 – only included
ƒ
with Terminal Strip models)
Drill with various bits for mounting hardware
ƒ
Mounting hardware
ƒ
Reader spacer when mounting on or near
ƒ
metal or metal junction boxes (refer to How
to Order Guide)
IP65 Mounting gasket, recommended for
ƒ
outdoor installation
ƒ
Junction box
Junction box
not included
Optional gasket
An ASSA ABLOY Group brand
2
Wire the reader
Pigtail version
18"
(0.46m)
PIGTAIL***
TERMINAL
Yellow
P1-1
Beeper Input
Orange
P1-2
LED Input (GRN)
Black
P1-3
Ground (RTN)
Red
P1-4
+VDC
Drain
P1-5
Unused
Brown
P1-6
LED Input (RED)
Blue
P1-7
Hold Input
Red/Green
P2-7
GPI01/OSDP (RS485-FDX/HDX-A)
Tan
P2-6
GPI02/OSDP (RS485-FDX-HDX-B)
Violet
P2-5
*Open Collector Output/Tamper
White
P2-4
**Wiegand Data 1 / Clock
Green
P2-3
**Wiegand Data 0 / Data
Pink
P2-2
GPI03 (RS485-FDX-Z)
Gray
P2-1
GPI04 (RS485-FDX-Y)
Note: Previous iCLASS readers had reversed RS-485 wiring (P2-7 & P2-6 - A & B). When
upgrading to an iCLASS SE reader, ensure proper connections as defined below.
Note: It's possible to reuse existing Wiegand wiring for OSDP, however, using simple stranded
cable typical of Wiegand access control readers is usually not meeting the RS485 twisted pair
recommendations.
Note: For OSDP cable lengths greater than 200ft. (61M) or EMF interference, install 120Ω +/- 2Ω
resistor across RS-485 termination ends.
Note: Wiring the reader incorrectly may permanently damage the reader.
Note: With a keypad reader, operating as 26 bit emulation; upon power up you have 5 seconds
to enter the facility code followed by #. If unsuccessful, the reader LED displays solid Red.
Power-cycle the reader and retry entering the facility code.
The facility code needs to be manually entered as 3 digits (i.e. if facility code is 10 enter 0-1-0-
#). Note: SE readers only use facility codes between 1-255, and there is no default facility code.
Once the facility code has been entered, the LED will display Violet and then to a final Red. Then
power-cycle the reader. Note: When using a keypad, if there are 2 short beeps after entering your
PIN, the reader does not have a facility code configured yet. In this event, an Admin will need to
be power-cycle the reader and enter the facility code before the reader will accept your PIN.
3
Secure the reader to the backplate
1
2
3
4
Power and test the reader
Turn on the power.
The reader should
beep three times
and the light bar
should flash three
times.
Terminal Strip version
BEEP
GRN
GND
+VDC
DRAIN
RED
HOLD
DESCRIPTION
* Tamper Output. When
activated, output syncs to
ground (default).
** Dependent upon
reader configuration.
See HTOG Wiegand
and Clock-and-Data
configurations for more
information.
*** For 5 meter pigtail readers
(PN: 9xxxxxLEKxxxxx),
follow the wiring diagram
on the reader.
1. Align the top of the reader with the top of the
backplate.
2. Align the bottom of reader with the bottom of
the backplate.
3. Secure the reader to the backplate using one of
the supplied screws:
Security/non-tamper screw:
0.138-32 x 0.375" screw (supplied)
Non-security/standard screw: 0.138-32 x 0.375"
screws (supplied)
Test the reader with
a card. The buzzer
should beep and the
LED should flash.
GPI01
GPI02
OC/TMPR
DATA1/CLK
DATA0/DATA
GPI03
GPI04