Gainlab Audio DICTATOR GLA-TC1 Calibration Manual - Page 16

Browse online or download pdf Calibration Manual for Recording Equipment Gainlab Audio DICTATOR GLA-TC1. Gainlab Audio DICTATOR GLA-TC1 18 pages.

Switch mode to Bypass!
Adjust: VR11 (for left channel) and VR13 (for right channel)
Measure: 0dBU on a VU meters
Switch mode to LoComp!
Adjust: VR12 (for left channel) and VR14 (for right channel)
Measure: -3dBU on a VU meters reduction scale
Go back to Bypass mode and check if it needs repeated adjustment until you see that the VU
meter works correctly.
THAT'S IT! YOU ARE DONE NOW.
YOU CAN LISTEN TO YOUR FAVORITE TRACK THROUGH THE UNIT FOR CHECKING SONICAL PERFORMANCE.
If you have further questions or stucked somewhere in the procedure then please reach GAINLAB AUDIO
through
.