DynaLock 1661 Series Installation Instructions

Browse online or download pdf Installation Instructions for Door locks DynaLock 1661 Series. DynaLock 1661 Series 2 pages. Commercial electric strike centerline latch entry for rim exit device

DynaLock 1661 Series Installation Instructions
1661 SERIES COMMERCIAL ELECTRIC STRIKE
CENTERLINE LATCH ENTRY FOR RIM EXIT DEVICE
1. For new installations, surface mount 1661 strike first, then install exit device accordingly maintaining a
minimum of
" clearance.
3
1 6
2. Determine the horizontal center line 'G' of the Pullman Latch of the exit device, and transfer to frame stop.
(see fig. 1)
3. Determine the vertical center line of the Electric Strike 'X' by adding
and measure from the push side of the door to frame stop for 'X'.
4. Prepare door jamb as per template drawing for full surface mounting. (see preparation "V")
5. Ensure that strike insert is placed in the center most position on the faceplate prior to installation.
This allows for maximum adjustability when installation is complete (see Fig. 2).
6. Connect wires from power source to terminal screws on strike (polarity is not observed).
7. Using slotted holes in chassis, install exit device electric strike with 2 SHCS
screws provided.
8. Adjust chassis and electric insert (if necessary), horizontally, until Pullman Latch engages when door is
closed. Finally tighten screws.
Important: Be sure exit device dead locks when door is closed before proceeding to step 9.
9. Mark, drill and tap for the locking screws provided, and install to secure final location with
2 SHCS
1
- 20 x 1", screws provided.
4
Note:
If further adjustment is needed later, to correct door or weatherstrip misalignments, horizontally move
insert on its furrows by loosening screws under the face plate, and re-tighten when in the corrected
position (Fig. 2.).
Important:
The 1661 Electric Strike is never to be used as a door stop. Please install stops on frame in appropriate
locations. Ensure the exit device functions as intended for life safety concerns by verifying electric strike
and exit device compatibility. Maximum latch projection is essential to obtain full holding force.
705 EMMETT ST. P.O.BOX 2728 BRISTOL, CT 06011-2728 USA PHONE: 860-582-4761 FAX: 860-585-0338 EMAIL [email protected]
Installation Instructions
©2005 DYNALOCK WWW.DYNALOCK.COM
" to dimension "R" (See Fig.1)
3
4
1
- 20 x 1", socket head cap
4