Connection Diagram 4000 Panel Mount and 4050 Controller

ED-56816
Note 1: This Equipment must be installed in compliance with National electrical code and all applicable
state and local codes
Note 2: Transformer may be supplied as a winding in the ac motor or as a separate item. Standard
connections to winding in mechanical unit and loose transformer connections are both shown above.
Note 3: Dancer Position pot R5 is shown wired for winder operation. For use with payoff, pot rotation will
be reversed- rotating the Dancer Position pot R5 toward the zero (P1) and will cause the dancer to rise
Note 4: Values shown are typical. See BOM for actual values
5