Analog 0–5 V Speed Mode
DM805-AI
Low/High Speed Mode
DM805-AI
External Potentiometer Mode
DM805-AI
Leadshine Stepper Drives Quick Start Guide – First Edition – 11/04/2019
Accel/Ramp
Accel
Decel/LoSpeed
Decel
HiSpeed
Maximum Speed (when Analog
Input = 5V)
COM+
Run/Stop/Pulse
Direction/+Limit
Direction
Speed/(-)Limit
-Limit
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Ramp
Accel/Ramp
LoSpeed
DecelLoSpeed
HiSpeed
HiSpeed
COM+
Run/Stop/Pulse
Direction/+Limit
Direction
Speed/(-)Limit
Speed
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Accel/Ramp
Accel
Decel/LoSpeed
Decel
HiSpeed
Maximum Speed [when Analog input = 0V
(negative direction) or 5V (positive direction)]
COM+
Run/Stop/Pulse
Direction/+Limit
+Limit
Speed/(-)Limit
-Limit
Enable/Disable
Disable
Signal GND
+5V Output
0~5V Input
10k
Signal GND
Signal GND
Power GND
+20-80VDC
Motor A+
Motor A-
Motor
Motor B+
Motor B-
Leadshine Stepper Drives Quick Start Guide
Run
0~5V
20-80 VDC
Input
Multi-Function Inputs
Run/Stop Inputs
Run
Limits Inputs
20-80 VDC
Enable/Disable Inputs
Run
0-2.5V Negative
2.5-5V Positive
20-80 VDC
Mode Diagram Overview
Description
The active function of each
input is shown next to the
external switches in the Mode
diagrams� Example: In Analog
0-5V Speed Mode, the inputs'
functions are Run, Direction,
-Limit, and Disable�
The Run/Stop function (in
analog modes) uses accel
and decel ramps to transition
speed�
The Limit inputs are direction-
sensitive and are Normally
Open (they allow motion if
left unconnected)� The Limit
function uses decel and accel
ramps� Note that only the
-Limit is available in Analog
0-5V Speed Mode�
This input is often left
unconnected� The Disable
input does not use a decel
ramp (stops quickly), but does
use an accel ramp to restart�
Once the drive is disabled, the
Run input should be removed
before the drive is re-enabled�
Otherwise, the drive may lose
synchronization with the motor
on restart (if accel or set speed
is high)�
Page 12 of 17