c) Go to "[07] Alarms" menu on the display and set the REFL Warning to 100%.
Fig. 21 – Set REFL warning
d) Press RF ON/OFF button on the front panel to enable the RF.
e) Disconnect the 50ohm load from the rear of the amplifier.
f) On the 001-000166-02 board adjust the RT5 trimmer to set the reflected power at the
same value of the forward power (ex: FWD power: 250W = RFL power: 250W).
Fig. 22 – Control board RT5 adjust
Mozart series calibrating procedure
17 /19