5.3.4 Connecting the inlet and outlet line

As mentioned in section 5.3., the inlet and outlet connections must be
carried out using a flexible tube to connect the fixed installation to the
softener. Although it isn't necessary as the system has its own bypass
system, it is recommended to
able to cut off all of the treatment systems (normally the softener and
prefilter) from the water installation if necessary.
Hidro-Water recommends the use of female-female or female-male
flexible hoses depending on what is required for the current installation.
That way, we isolate the transmission of possible vibrations between the
installation and the system.
Make sure the female connection has its corresponding rubber washer
and the male (is so) is correctly sealed (you can use a paste, tape, Teflon®
thread sealant or whatever you prefer) to avoid water leaks.

5.3.5 Connecting the drainage line (drain)

The system should be placed as close to a drain as possible. The ideal connection that is
recommended by the manufacturer is directly above and no more than 3 meters away from the
draining point. The drainage line connection will be made with a 13mm (interior diameter) flexible
tube (we recommend a 17x13 transparent PVC flexible tube. To do so, the nut and the tube
support must be inserted (item number 4 of the accessories shown in section 5.1 'unpacking'),
through one end of the inner 13mm flexible tube, and screw it into the drain outlet valve. If you
prefer to use other another type of tube, the thread of the drain outlet is a ¾" male thread.
The drainage level will be below the softener's outlet valve. If not, please contact our
technical department.
The softener's drainage connection and the brine tank's overflow line lead to the
drain. Both lines should be independent and should not be connected. Both lines
must have a direct discharge to avoid anything coming back up.
12
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01
make an external bypass system to be

5.3.6 Connecting the overflow line

The brine tank's safety overflow leads the overflow to
the drain instead of being spilt all over the floor. To connect
the overflow line, connect a tube or hose with an interior
diameter or 13mm and lead it to the drain (we recommend
a 17x13 transparent PVC flexible tube).
Do not connect the overflow line to the control unit's drainage line. The
overflow line must be a direct line and separate to the drainage line leading
to the general drain.
Always leave an air space between the drainage tube
and the general drain to avoid the possibility of anything
coming back up the drain. This could affect the systems
normal functionality.

5.3.7 Connecting the brine line

The head must be connected to the brine valve located in
the salt tank to a polythene tube using two QF connectors
(quick connection ends). This tube is factory installed,
but due to its relevance in the correct functioning of
the equipment, we recommend checking the correct
connection at both ends. The tube must be inserted all
the way; Retract it slightly to confirm that it is correctly
connected.
You must assure that all of the accessories and couplings are correctly connected to avoid
taking in air.

5.4.- Electrical connection

Once the previous connections have been made, the water softener's programmer valve
must be connected to the 230V ac 50Hz power supply, using the transformer supplied with it.
The electrical installation of the equipment is carried out following the appropriate electrical
installation regulations. The appropriate protection devices (a miniature circuit breaker (MCB)
and differential) must be provided in the supply line.
The equipment will be connected to an independent lighting line powered 24 hours
a day, NEVER on any line connected to motors.
MA-EN-DESCALCIFICADOR KOBE (USR) UF-3004-XX JD18V01