Trouble Shooting Guide
SYMPTOMS
Water leaks from
handle position
Water leaks from the
top lid of the filter
Sand media leaking
from drain outlet
Water leaks from
drain outlet
PROBABLE CAUSES
1. the ring under the standard lid of
handle is damaged. ( Please see
Figure 3, Item No. 3-Washer for
Handle)
1. The O-Ring for 1.5"Valve rotor
cover is not sealed well. (Please see
Figure 3, Item No.14-Washer for
spring)
2. Item No.14-Washer for spring is
damaged.
1. The sand media diameter is too
small.
2. The laterals are damaged. (Please
see Figure 2, item No.11-Laterals).
1. The spider gasket is loose or
damaged.
(Please see Figure 3, Item No.18-
Spider Gasket)
ACTION TO BE TAKEN
1. Replace item No.3 washer
(Please see Figure 3)
1. Check if the washer for spring is
sealed well and adjust it.
2. Replace item No.14 washer for
spring.(Please see Figure 3)
1. Check if the sand media
diameter is too small or not.
2. If water outlet pipe also leaking,
that means the laterals are broken,
please replace these. (See Figure
2, item No.11-Laterals)
1. Check if the spider gasket is
loose or not, adjust it.
2. If it was damaged please replace
it.(See Figure 3, Item No.18-Spider
Gasket).