HIFEI Technology SwordfishX 200A-8S Instructions - Page 2
Browse online or download pdf Instructions for Controller HIFEI Technology SwordfishX 200A-8S. HIFEI Technology SwordfishX 200A-8S 2 pages. Brushless esc
BRUSHLESS ESC INSTRUCTIONS
Connect ESC to PC
①
Step①: Correctly connect ESC‟s Wifi wire/to USB adaptor wire to USB adaptor
Step②:Plug the USB side of USB Linker to one of computer‟s USB ports.
Step③:Run software "Hifei V6.xx".
Note: 'Please read USB adaptor user manuals for more information.
Install Hifei software
Download the setup software of „Hifei V6.xx‟ from website (Support column) and finish the
installation according to the popped-up window guide.
When installation is finished, „Hifei V6.xx‟ software icon
desktop.
Note: a. If PC OS is Windows 7,8,10, it is suggested to install V6.xx to administrator.
b. If you once changed PC font to big size, then it needs to change it to normal size. Because big size
font would possibly cause software interface cannot be showed in full.
V6.0 tab 5 Upgrade
In tab 5, you can upgrade ESC‟s firmware if there is a new firmware for the ESC be
released.
When upgrade the ESC, it needs to connect the cable to receiver with upgrade
cable together. (Pls refer to the below diagram)
Each ESC has specific firmware and be different. You have to make sure the firmware
you chose is correct. Otherwise possibly causing ESC damage.
①
②
Step①: Short upgrade cable with receiver wire.
Step②: Connect ESC‟s Wifi wire/to USB adaptor wire to USB adaptor
Step③: Plug the USB Adapter to an USB port of PC.
Parameters features
③
LVC (1)
Cutoff
voltage/ cell
Brake Type
②
Current
limitation
Timing
Active Free
Wheeling
Cutoff Type
Startup
PWM Rate
Note: a. The parameters with * behind are the ESC's default settings.
is auto saved on computer
b. When the 'LVC' of ESC is set at 'Auto' detect, after the two power beeps the ESC will beep
the number of Lipo cells which the auto detect feature detects, and the red LED on ESC will
blink in accompany with the beeps. '3.0v' is the default cut-off voltage of per Lipo cell when
the LVC is set at 'Auto' detect.
Eg: If you connect the ESC to a 4s Lipo battery pack, the motor will firstly emit ♪ ♪ , then
detect the Lipo numbers ♪ ♪ ♪ ♪ , and the red LED will blink four times. The low voltage
cut-off is calculated as '12.0V'.
c. Please ensure only when the battery packs is fully charged and it can set the LVC at 'Auto',
it is recommended to set the LVC at actual Lipo cells once the battery pack is over 4S cells.
Low voltage cut-off
The setting of LVC can protect battery from discharging too low and causing
permanent damage to battery, especially for Lithium polymer cells. It is
strongly recommended to set the LVC carefully before running.
Cutoff voltage/ cell
The setting is to set the low voltage cut-off of each Lipo cell.
e.g. If set the LVC of per Lipo cell at „2.8v‟, the LVC is set at „2s cells‟, then
the cut-off voltage of the whole battery pack is "2.8*2"=5.6v.
Brake type
③
'Brake disabled' setting will close the brake function;
'Soft brake' will provide 20% of full braking power.
'Hard brake' will provide 100% of full braking power.
Timing advance
'Low timing' setting adjusts the timing at the range of 0º~15º, recommended
for more lower pole count brushless motors (such as 2 poles, or 4 poles). It
gives more power and slightly less efficient;
'Middle timing' adjusts the timing at the range of 5º~20º, recommended for
most brushless motors. It gives a good balance of power and efficiency;
'High timing' adjusts the timing at the range of 15º~30º, recommended for
higher pole count motors. (such as 8, 10, 12, 14 poles or higher brushless
'Auto timing' setting is automatically adjust the timing degree according to
motor‟s rotating demand. 0º; 2º; 4º; 6º; 8º; 10º; 12º; 14º; 16º; 18º; 20º; 22º;
24º; 26º; 28º; 30º. (This setting can be only set via software „Hifei V4.xx . If
you want to upgrade your old software .please download Hifei software from
5.0V
2s
7.2V
8.4V
3s
4s
Auto
Lipos*
Lipos
Lipos
2.5V
2.6V
2.7V
2.8V
2.9V
3.0V*
3.1V
Close *
Soft brake
Hard brake
Low
Medium
High
Disabled*
Low
Middle
High
Auto *
ON
OFF*
Hard cutoff *
Soft cutoff
Soft start
Standard *
Fast start
8KHz *
12KHz
16KHz
Page 2
Cutoff type
Cutoff type settings decide the way in which the ESC cutoff output to brushless
5s
6s
motor when the LVC works, or temperature/ signal-lost protection works.
Lipos
Lipos
'Hard cutoff' : when the battery volts discharges to the set LVC value or soft protec-
tion works, the motor will shut down immediately. Motor can be restarted by closing
3.2V
3.3V
the throttle to the lowest position and re-move the throttle as normal.
'Soft cutoff': when the battery volts discharges to the set LVC value or soft protection
works, the ESC will slowly reduce motor power to zero, you will notice a decrease in
power and it is time to dock.
Startup type
0~30
'Soft start': very soft and smoothly start the motor, it will take more time.
'Standard start': start the motor at normal speed, it depends on the motor's quality
and dynamic response.
'Fast start': start the motor fast, it is recommended for racing.
PWM rate
8KHz is recommended for most brushless motors.
12KHz is recommended for low inductance motors. (e.g. 8,10,12,14 poles brushless
outrunner motors)
16KHz is recommended for very low inductance motors. (e.g. 16,18,20,24 poles
brushless outrunner motors)
Note: a. The poles mentioned above is the magnetic poles of brushless motor, but not the stator
numbers of motor.
b. High PWM rate is easier to make motor produce more heat. Cooling jacket for motor is very
important, and please be more carefully to choose high PWM rate.
c. It is strongly RECOMMENDED to have bench testing and choose appreciate parameters for
your configuration before assembling the ESC to hull for running.
V6.0 tab 3 Logger Configuration
Cycle Record 1) Not Reverse indicates when data logger memory space is filled
up, it will stop logging.
2) Reverse indicates when data logger memory space is filled up, it continue
logging data indefinitely by overlapping the former data and do a cycle. Default
setting is Not Reverse.
means the times that data logger samples per second. Default
Sampling rate
setting is 3ps. *
* Higher sampling rate will fill up the memory space quickly and thus reduce the logging
time when in 'not reverse' record type.
Sampling Rate
Once/ second
Twice/second
3 times/second Approx. 22.7 min-
Not Re-
verse
4 times/second
Record
10 times/second
15 times/second
30 times/second
Minimum running Time means the minimum time that ESC is requested to
run. The time MUST be longer than reference in above form. Too short run-
ning will cause ESC logs little data that cannot be displayed in PC windows.
www.hifei.com
Max logging Time
Mini running Time
Approx. 68.1 minutes
> 60 seconds
Approx. 34.05 minutes
> 30 seconds
> 20 seconds
Approx. 13.62 minutes
> 10 seconds
Approx. 6.81 minutes
> 5 seconds
Approx. 3.405 minutes
> 3 seconds
Approx. 2.27 minutes
> 2 seconds