HIFEI Technology 160A-KIII Pro-HV Instructions Manual - Page 2

Browse online or download pdf Instructions Manual for Remote Control HIFEI Technology 160A-KIII Pro-HV. HIFEI Technology 160A-KIII Pro-HV 10 pages.

Mounting the ESC
Recommend to use Velcro to fix the ESC on fuselage for easy
removal. keep the good airflow around the ESC.
Calibrating throttle range of TX
You MUST complete throttle range calibration before use a
new ESC at first time, and when change a new radio.
Connect ESC to motor, plug receiver lead of ESC to
1st:
throttle channel of receiver.
2nd Push joystick of transmitter to max throttle position,
power on transmitter.
3rd: Power on receiver, connect ESC to battery. Motor emits
three beeps in drop tones.
In the following, motor will emit four long beeps in flat
4th:
tones.
During any one beep of the four long beeps, pull down
joystick to zero position immediately.
5th: Then motor emits two beeps in up tones.
Calibrating is completed, it‟s ready to fly.
Parameters features
Kingkong III Pro ESC come with default factory settings
which are recommended for most applications. The program-
ming options are provided for obtain optimum performance in
different setup.
Low voltage cutoff
Option 1: Auto
Option 3: 5s Lipo
Option 5: 7s Lipo
Option 7: 9s Lipo
Option 9: 11s Lipo
Option 11: 13s Lipo
Option 13: 15s Lipo
Option 15: 17s Lipo
Option 17: 19s Lipo
Recommended to set LVC at exact Lipos series number for
!
better protect Lipo packs from over-discharging. ONLY
WHEN battery packs are fully charged, 'Auto' can detect
Lipo cells number correctly and it is suggested under this
condition.
Kingkong III Pro USER MANUALS
Option
2:
4s
Lipo
(default)
Option 4: 6s Lipo
Option 6: 8s Lipo
Option 8: 10s Lipo
Option10: 12s Lipo
Option12: 14s Lipo
Option14: 16s Lipo
Option16: 18s Lipo
Option18: 20s Lipo
Lipo cell Cutoff Voltage
Option 1: 2.5v
Option 3: 2.7v
Option 5: 2.9v
Option 7: 3.1v
Option 9: 3.3v

Current Limiting

Option 1:
very sensitivity
Option 2: standard
(default)
Option 3:
Insensitivity
Option 4: disabled
*
Default setting is recommended. If you change the setting, damage to the
controller as a result of over current will be not covered by the manufactur-
er's warranty.
Brake
Option 1:
Disabled (default)
Option 2:
Soft brake
Option 3:
Hard brake
Timing Advance
Option 1: Low
(0°~15°)
Option 2: middle
(5 °~ 20 °)
Option 3: High
(15° ~ 30 °)
Option4:Auto(default)
Option 5: 0°; Option 6: 2°; Option 7: 4°; Option 8: 6°; Option 9:
8°; Option 10: 10°; Option 11: 12°; Option 12: 14°; Option 13:
16°; Option 14: 18°; Option 15: 20°; Option 16: 22°; Option 17:
24°; Option 18: 26°; Option 19: 28°; Option 20: 30°
0° and 30° timings are for special motors. ONLY when mo-
!
tor manufacturer requests the special timings, they can be
used.
www.hifei.com
Option 2: 2.6v
Option 4: 2.8v
Option 6: 3.0v (default)
Option 8: 3.2v
Low over-current threshold, will shut
down rapidly
Moderate over-current threshold, will
shut down after a slight delay. Recom-
mended for inrunner motors.
High over-current threshold, will shut
down after a slight delay,. Recommended
for outrunner motors. Only experienced
modelers should use this option.
Current limiting detection disabled. Only
experienced modelers should use this
option.
Brake disabled is mainly used for heli-
copters.
Soft brake provides 50% of full braking
power. General aircraft use, with fixed or
folding prop
Hard brake is 70% braking power. Direct
drive applications where more braking
power is required. Hard brake should
only be used below 12V.
Recommended for lower pole count
motors. Gives more power and slight-
ly less efficient.
Recommended
for
tors .Gives a good balance of power
and efficiency.
Recommended for most of higher
pole count motors
Recommended for most of all brush-
less motors.
most
mo-
Page 2