Installation Step 3. Installation
■ DIN rail installation
• Installation
• Remove
②
①
■ Mounting with bolt
• Mounting is possible by using bracket. The method of mounting and detaching is as
same as DIN rail.
Installation Step 4. Connection
• Supply power after installation.
Color
Description
Brown
Power: 10 - 30 VDCᜡ
Blue
Common GND (Input/Output/Power)
Black
HIGH judgment output
Orange
LOW judgment Output
Gray
GO judgment Output
Green
Alarm output
White
Analog output
Shield
Analog output GND
01)
Pink
External input1
Yellow
External input2
Red
External input3
Purple
External input4
01) It is needed to distinguish from common GND.
Display & Mode Setting when Power is ON
• Setting control output type when connecting a sensor head and supplying power at
the first time, or replacing a sensor head.
Changes setting value, [MODE]
• [▲], [▼] key:
the next
• For details of Mode setting and parameter, refer to the user manual.
• The version information displays right after supplying the power.
Parameter
Display
Default
Version information
Version Displays firmware version
VER
Control output type
OUT
Analog control
output type
A-OUT
Mode Setting
Change SV display
[◀ / ▶]
→
[◀ / ▶] over 3 sec
→
Key lock
Emission
[AUTO] over 5 sec
→
optimization
Zero-point
[ZERO] over 2 sec
→
adjustment
[MODE]+ [▲]
HIGH sensitivity
→
over 2 sec
adjustment
RUN
[MODE]+ [▼]
LOW sensitivity
→
over 2 sec
adjustment
Auto sensitivity
[MODE] within 2 sec →
(Teaching)
[MODE]+[AUTO]
Control / Analog
→
over 2 sec
output type
[▲]
→
HIGH PEAK value
[▼]
→
LOW PEAK value
[MODE] over 2 sec
→
Parameter group
1. Insert the bottom holder of amplifier unit to
35 mm width DIN rail.
2. Push the front part of the unit to arrow
direction to mount.
1.
①
Side amplifier unit to
direction.
2.
②
Pull the assembly part to
detach.
Ecternal input □:
OFF, Hold trigger, Output reset, Laser
OFF, Zero-point adjustment, BANK-
A/B combinations
: Saves the setting value and move to
key
Description
NPN NPN, PNP
OFF, 4 - 20 mA, 0 - 5 V, 1 - 5 V, -5 - 5 V
• After 'OUT.SET' flashed 3 times and it returns
OFF
to the run mode
value
Completed: OK Marked and
return
Failed: Return after displaying
FAIL, please try again.
ZERO → Return after
displaying 0000
[MODE] key within 2 sec
Auto
PV display: OUT.SET
SV display: After 'END' is
flashed 3 times and it returns
automatically
[◀ / ▶ / ▼/ ▲] or auto after
no key input for 5 sec
[MODE] key over 3 sec
Parameter Setting
• Some parameter are activated / deactivated depending on other parameters.
• [MODE] key: Enters parameter group, save and return to the upper step (over 3 sec)
[◀], [▶] key: Changes parameter group, parameter
[▲], [▼] key: Changes setting value of parameter
• Some parameters/functions only support only over 5.0 firmware version.
• Some default value is varied by connected sensor head model.
■ Parameter group 1
Parameter
Response time
Teaching mode
Output type
PV display
Display digit
direction to
Display scale low
limit
Display scale high
limit
Hysteresis
Analog output
scale low limit
Analog output
scale high limit
Error output
displacement
Fixed error output
_Analog
Fixed error output
_Judgment
Item
Offset
Power
■ Parameter group 3
Parameter
External input 1
External input 2
Output
External input 3
External input 4
Error
External
input
In error status, 'ERROR' is displayed on PV display.
Deal with an error by referring to the below solution of each setting value SV display.
SV
Output Causes
display
O
HEAD
O
LASER
DARK
-
RANGE
-
BRIGHT
-
------
O
A-MEM
O
H-MEM
O
→
AMP-C
O
VER
→
O
OUT
→
RUN
O
AMP
→
O
oCUR
→
O
AIF
→
→
18, Bansong-ro 513Beon-gil, Haeundae-gu, Busan, Republic of Korea, 48002
www.autonics.com | +82-2-2048-1577 | [email protected]
■ Parameter group 2
Display
Default
Parameter
RSPD Varied model
Calculation
Gain
SENS
1PNT
Filter
NoNC
NO
Samples for
DISP
STND
averaging
DOT Varied model
Samples for
median
H-SC
Varied model
Hold
Hold timing input
L-SC
HYS Varied model
Auto trigger level
Auto trigger
hysteresis
H-AN
Varied model
Timer
Timer value
L-AN
ERrOUT
KEEP
FIxOUT Max. value
FIxOU2
GO
OFFSET Varied model
■ Parameter group 4
Display
Default
Parameter
Display direction
D-IN1
OFF
Bank
D-IN2
OFF
Saving mode
D-IN3
OFF
Lock mode
D-IN4
OFF
Initialize
Troubleshooting
Disconnection of sensor
Check the connection between sensor head and
head/amplifier unit/cable
amplifier unit.
Sensor head malfunction
Check the disconnection of sensor head cable.
Perform the above items and supply the power
again.
If the problem is not resolved after the above items
Malfunction of emission
are performed, it is judged that the sensor head is
defective and needs to be replaced.
Not existing the object or
background in maximum
Adjust the distance between sensor head and object
measurement range
in the maximum measurement range.
Over receive the light
In status of display
Return to status of present value display available.
unavailable
Amplifier unit memory
Turn off the power, check the connection of sensor
malfunction
head, and supply the power again.
(EEPROM cannot be
Executes the initialize function in parameter group 4.
refreshed due to exceeding
If the problem is not resolved after the above items
the number of recording
are performed, it is judged that the amplifier unit is
over 1 million times)
defective and needs to be replaced.
Turn off the power, check the connection of sensor
head, and supply the power again.
Sensor head memory
If the problem is not resolved after the above item
malfunction
is performed, it is judged that the amplifier unit is
defective and needs to be replaced.
After turn off the power, check the connection
Poor connection between
between amplifier units, and supply the power
amplifier units
again.
Firmware version
Check the firmware version and needs to update
incompatible
to compatible version.
After turn off the power, check connection of HIGH
Disconnection of the
(black) / GO (gray) / LOW (orange) wire, and supply
judgment output
the power again.
After turn off the power, check the connection of
sensor head, and supply the power again.
Amplifier unit error
If the problem is not resolved after the above items
are performed, it is judged that the amplifier unit is
defective and needs to be replaced.
Over current of output
Check the load of output is specification range.
terminal
Check the output is contacted other wire or frame.
Poor connection between
After turn off the power, check the connection
amplifier units or
between amplifier units or communication module,
communication module
and supply the power again.
Display
Default
CALC
OFF
GAIN
1
FILTER
AVF
AVF
16
MEDIAN
OFF
HOLD
OFF
HOLdT
T-IN
AtLV
0
AtHYS Varied model
T-MOD
OFF
TIME
0
Display
Default
DIR Normal
BANK
BANK-0
SAVE
OFF
LOCK
OFF
INIT