Dynamis lead-line Technical Manual - Page 14

Browse online or download pdf Technical Manual for Camera Accessories Dynamis lead-line. Dynamis lead-line 16 pages. Sealed lead acid batteries

If remedy of such kind of battery is desired, please contact our Company.
To evaluate batteries with voltages higher than the above-mentioned value,
fully recharge the battery before any measurements.
If the fully recharge of batteries is not possible, batteries with OCV or
internal resistance values far from its average values can be classified as
defective batteries.
The OCV should be measured one hour (24 hours is better) after recharge.
The fully charged battery with OCV smaller than 6.2V(for 6V battery) or
12.5V(for 12V battery) is a defective battery.
The fully charged battery should have OCV higher than 6.45V(for 6V
battery) or 12.9V(for 12V battery). If the battery has values between 6.2 ~
6.45V(for 6V battery) or 12.5 ~ 12.9V(for 12V battery), it may not be fully
charged, and may need a recharge with proper charger. If this condition is not
improved, the battery's capacity may have been reduced.
The remedy method for charging the hard-to-recharge battery is available
through contact with our Company.

5.3 The recycling of batteries

 The defective and used batteries shall be recycled.
 When recycling batteries, the battery terminals should have insulation
treatments. The batteries have residual capacity even for the used batteries.
Batteries with terminals not insulated may cause danger of explosion or fire.
It is lawful for people to return the scrap batteries to the sale store for
recycling.