DBK Drymatic Boost Bar FGPH105 Instruction Manual - Page 14
Browse online or download pdf Instruction Manual for Dryer DBK Drymatic Boost Bar FGPH105. DBK Drymatic Boost Bar FGPH105 18 pages. Adaptable heat drying system
About the Memory - Drymatic Boost Bar has a built in memory allowing it to continue and restart jobs even if power is lost
or removed. This ensures that the machine doesn't forget kWh and hours data and continues on with the same settings that
were programmed by the technician.
Job Memory - Keeps track of all kWh/hours data and also the machine settings that were programmed by the technician.
This data should be reset at either the start of the new job or end of the previous job to ensure that the next jobs starts
fresh. This can be reset from the main display, failure to do so could cause confusion with data.
Note - The Maximum Temperature setting will come in to effect when the Air Outlet temperature exceeds the temperature
selected by the user. The Boost Bar will ramp down heater power to keep the Air Off temperature below the desired level.
Machine Status Ribbon
The machine status ribbon shows the machines current operating state, operating mode and the heater power level. This
table shows all possible situations.
Machine Status:
Machine Running
Machine Stopped
User Maintenance:
WARNING: The unit must be unplugged before performing any form of maintenance or cleaning.
Before each use:
Inspect the power cord for any sign of damage. If the cord looks broken, frayed or worn do not use the product and seek a
replacement. Cords should only be replaced by the manufacturer, if cord is damaged please contact your local Drymatic
representative.
Cleaning:
The housing can be cleaned with a mild detergent and warm water. Do not use liquids on the grills and metal plates, these can
be cleaned with a soft cloth. Never use a hose to clean the unit and ensure that it is completely dry before use.
Replacing the Fuse:
The on board fuse can be changed by: 1) Isolating the unit from the mains supply. 2)Using a flat head screwdriver to open the
fuse holder. 3) Remove the old fuse and replace with new one. 4) Close the fuse holder with screwdriver. Replacement fuses
must be 15A, 250V or 500V fast blow ceramic types (DBK part number: EC308).
In the event of damage, repairs or any other maintenance requirements please contact your local Drymatic representative.
No aftermarket repair on this product should be carried out by the user.
Description:
Machine running as normal.
Machine on hold, press play to re-
sume.
Heater Level:
13
Description:
Full Heater Power
66% Heater Power (80% for
Aus/Scan models)
33% Heater Power (40% for
Aus/Scan models)
Heater Off