GALAXIS SHOWTECHNIK PYROTEC PFS Pocket User Manual - Page 4

Browse online or download pdf User Manual for Transmitter GALAXIS SHOWTECHNIK PYROTEC PFS Pocket. GALAXIS SHOWTECHNIK PYROTEC PFS Pocket 17 pages.

- 4 -
8. The components of our firing system are to be covered or
protected from burn-off cinders, debris and weather conditions where
necessary. Electrical contacts should be protected from corrosion,
soiling, damage, and they should be cleaned regularly.
9. The contacts of the pyrotechnical articles or their e-matches,
which have not yet been connected, must always be short circuited
(shunted).
10. We recommend having our products inspected every one to two
years. Along with the testing of the batteries, a visual test as
well as a functional test will prove that the unit is functioning
safely and correctly.
11. Do not use damaged or faulty equipment. If equipment is damaged
or faulty, return it to the manufacturer for professional repair.
Our warranty for the proper function for our equipment provides for
defective parts or faulty workmanship, and does not include
equipment or items that are damaged, or show signs of abuse.
12. Any changes made to the devices, or to the firing system as well
as repair work on the units other than that done by the manufacturer
will invalidate any warranty claims, and our products liability will
be void. Should repair of the units be necessary, then we do require
a detailed report of the problem.
13. Please make sure that when lending or renting equipment, that no
damage has occurred during the rental period of the units. Advise
your staff, that it is very important to report any possible damage
of the units immediately. Customers, that have borrowed or rented
the equipment are hereby informed, that it is their duty to report
any damage found or suspected on the unit when returning such.
14. Wire connections from the firing device to the e-matches should
always be insulated. Avoid wire damage, for example through heat,
cable twisting, cable pinching and burn-off cinders or through
forced piercing. All cables and wiring must be checked before use to
ensure that circuits are correctly wired, and within the correct
resistance limits. During repeated use of wires and cables we do
recommend a continuity and short circuit test between each insulated
connection before using it again.
15. The firing of igniters in accordance with 'SprengG' (i.e. German
explosive law) is not allowed with our products. For this purpose
only firing units with a BAM certification in accordance with §5
'SprengG' or equivalent are allowed. The same applies to high
explosives.
16. Avoid unintended firing through electrostatic charging. When
using e-matches, make sure that you only use those types which are
protected against unintended firing through electrostatic
discharges. The e-matches that you use should also have a BAM
certification or equivalent.
17. Avoid physical contact of e-matches or their firing lines with
other conductible materials if it is possible that either a static
discharge or potential equalization can arise.