Autonics TK4H-A4RR Product Manual - Page 4
Browse online or download pdf Product Manual for Temperature Controller Autonics TK4H-A4RR. Autonics TK4H-A4RR 6 pages. Simultaneous heating&cooling output pid temperature controllers
Connections
• Shaded terminals are standard model.
• Digital input is not electrically insulated from internal circuits, so it should be insulated
when connecting other circuits.
■ TK4N
CT
mA
V
TC
RTD
OUT2/AL1 OUT:
OUT1:
250 VACᜠ 3 A 1a
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
30 VDCᜡ 3 A 1a
RESISTIVE LOAD
RESISTIVE LOAD
■ TK4S
Digital Input
Digital Input
Contact,
Contact,
Non contact Input
Non contact Input
1
DI-1
DI-1
2
3
OUT1:Relay
Transfer
250 VACᜠ 3 A 1a
Output
30 VDCᜡ 3 A 1a
4
DC 4-20 mA
RESISTIVE LOAD
5
-
+
6
SOURCE
100-240 VACᜠ 50/60 Hz 8 VA
24 VACᜠ 50/60 Hz 8 VA
24-48 VDCᜡ 5 W
OUT1
SSR
Current
3
3
+
V
-
4
4
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500Ω Max.
■ TK4SP
6
5
OUT1: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
4
RESISTIVE LOAD
B'
3
V
B
2
mA
TC
1
A
RTD
OUT1
SSR
Current
5
5
+
V
-
4
4
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500 Ω Max.
■ TK4M
1
AL1 OUT:
250 VACᜠ 3 A 1a
RESISTIVE LOAD
2
AL2 OUT:
250 VACᜠ 3 A 1a
3
RESISTIVE LOAD
4
OUT2: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
5
RESISTIVE LOAD
6
OUT1: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
7
RESISTIVE LOAD
SOURCE
8
100-240 VACᜠ
-
50/60 Hz 8 VA
24 VACᜠ
+
9
50/60 Hz 8 VA
24-48 VDCᜡ 5 W
OUT1
SSR
Current
6
6
+
V
-
7
7
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500 Ω Max.
Transfer Output
DC 4-20 mA
S
S
Communication
Output
R
O
11 VDCᜡ±2V
U
20 mA Max.
Current Transformer
T
0.0-50.0 A
C
1
U
R
Digital Input
R
11 VDCᜡ±2V
Contact,
20 mA Max.
Non contact Input
S
S
R
O
AL2 OUT:
11 VDCᜡ±2V
250 VACᜠ 0.5 A 1a
U
20 mA Max.
RESISTIVE LOAD
T
C
2
SOURCE
U
100-240 VACᜠ
R
50/60 Hz 6 VA
R
11 VDCᜡ±2V
20 mA Max.
OUT2: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
RESISTIVE LOAD
13
7
AL1 OUT:
250 VACᜠ 3A 1a
DI-2
DI-2
14
8
RESISTIVE LOAD
AL2 OUT:
250 VACᜠ 3A 1a
9
15
RESISTIVE LOAD
RS485(A+)
mA
A
16
10
RS485(B-)
Communication
B
17
11
Output
CT
Current
B'
18
12
Transformer
0.0-50.0 A
RTD
OUT2
SSR
Current
13
13
+
+
+
V
mA
mA
-
-
-
14
14
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500Ω Max.
OUT2: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
RESISTIVE LOAD
7
AL1:
8
Relay
250 VACᜠ 3 A 1a
RESISTIVE LOAD
9
SOURCE
10
100-240 VACᜠ 50/60 Hz 8 VA
-
11
24 VACᜠ 50/60 Hz 8 VA
+
24-48 VDCᜡ 5 W
OUT2
SSR
Current
6
6
+
-
-
V
mA
mA
-
+
+
9
9
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500 Ω Max.
19
10
Digital Input
DI-1
DI-1
Contact,
20
11
Non contact Input
RS485(A+)
21
12
+
mA
RS485(B-)
22
13
-
Communication output
23
14
Current
Transformer
CT
24
15
0.0-50.0 A
A
25
16
+
B
26
17
mA
+
V
18
27
B'
-
RTD
TC
OUT2
SSR
Current
4
4
+
+
+
V
mA
mA
-
-
-
5
5
11 VDCᜡ±2V
DC 0/4-20 mA
20 mA Max.
Load 500 Ω Max.
■ TK4H / W / L
3
+
V
4
-
3
+
mA
4
-
1
+
V
-
2
1
+
mA
SOURCE
-
2
100-240 VACᜠ 50/60 Hz 8 VA
24 VACᜠ 50/60 Hz 8 VA
24-48 VDCᜡ 5 W
Crimp Terminal Specifications
• Unit: mm, Use the crimp terminal of follow shape.
mA
V
TC
≥3.0
≤5.8
Fork crimp terminal
Initial Display When Power is ON
When power is supplied, after all display will flash for 1 sec, model name is displayed
sequentially. After input sensor type will flash twice, enter into RUN mode.
PV display part ***8
SV display part ***8
Mode Setting
Auto before
entering to mode
(when using
password)
[◀], [▲], [▼]
RUN
[MODE] over 2 sec
[◀] + [▲] + [▼]
over 5 sec
[A/M]
01)
[▲] + [▼] over 3
Transfer Output
DC 4-20 mA
sec
01) In case of TK4N / 4S / 4SP model, short press of [MODE] key replaces [A/M] key function.
-
1
2
3
AL1 OUT:
250 VACᜠ 3 A 1a
4
RESISTIVE LOAD
5
AL2 OUT:
250 VACᜠ 3 A 1a
RESISTIVE LOAD
6
OUT2: Relay
7
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
8
RESISTIVE LOAD
9
OUT1: Relay
250 VACᜠ 3 A 1a
30 VDCᜡ 3 A 1a
10
RESISTIVE LOAD
11
-
+
12
OUT1
OUT2
SSR
Current
SSR
9
9
7
+
+
V
mA
10
-
10
-
8
11 VDCᜡ±2V
DC 0/4-20 mA
11 VDCᜡ±2V
20 mA Max.
Load 500 Ω Max.
20 mA Max.
1. All display
2. Model
TK4
14RN
Password Key input
Password
Pass
→
input
Fail
Move digits: [◀]
→
SV setting
Change value:
[▲], [▼]
Parameter
→
[MODE] over 3 sec
group
Parameter
→
Auto
reset
Auto/Manual
→
control
[A/M]
switching
Digital input
→
Auto
key
13
Digital Input
14
Contact,
Non contact Input
15
DI-1
DI-1
16
DI-2
DI-2
17
RS485(A+)
18
+
Transfer Out
mA
DC 4-20 mA
RS485(B-)
-
19
Communication output
20
Current
Transformer
CT
21
0.0-50.0 A
A
22
23
B
mA
V
B'
24
RTD
TC
Current
7
+
+
V
mA
-
8
-
DC 0/4-20 mA
Load 500 Ω Max.
≥3.0
≤5.8
Round crimp terminal
3. Input
4. Run mode
specification
TK4
OPEN
KCaH
0
Entering mode
Auto
Selected mode
[◀], [▲], [▼] Password input
[MODE]
Run mode
Save: [MODE]
→
or no key input
over 5 sec
→
→
RUN
→
→