Connecting to the cleaner
CAUTION:
· When tools did not connected to the cleaner,
please shut down the dust cover. Do not put
your fingers in the dust channel.
It is practical to connect the belt sander to cleaner
to use. Attention:
Connect the belt sander to cleaner as shown in the
figure 6. It is possible to purchase suitable hose to
connect tools and cleaner. Please according to the
relevant safety requirements for vacuuming
grinding operation and do some corresponding
protections to avoid the accidents.
Operation
CAUTION:
· Secure the workpiece with the fasteners like
clamp if there is any possibility of it moving
during the work operation.
· Do not make the power tool contract with the
workpiece before turning on or off the tool or it
may decrease the sanding efficiency or
damage the abrasive belt.
· When working with the tool, be very carefully
to avoid any contact of the tool and belt with
any part of your body or anything near you.
Hold the tool firmly with both hands. Turn the tool on and wait until it attains full speed before
operation. Then gently place the tool on the workpiece surface and move the tool back and forth.
(Fig.7) Press the belt only lightly on the workpiece. Excessive pressure may damage the belt and
shorten tool life.
Always use "A" range of the belt to sand the workpiece. (Fig.8)
MAINTENANCE AND INSPECTION
CAUTION:
· Always be sure that the tool is switched off and unplugged before carrying out any work on
the tool.
1. Inspecting the Mounting Screws
Regularly inspect all mounting screws and
ensure that they are properly tightened.
Should any of the screws be loose, retighten
them immediately. Failure to do so could
result in serious hazard.
2. Maintenance of the Motor
The motor unit winding is the very "heart" of
the power tool. Exercise due care to ensure
the winding does not become damaged and
/or wet with oil or water.
3. Inspecting and Replacing the Carbon Brushes
Remove and check the carbon brushes
regularly. Replace when they wear down to
the limit mark (Fig. 9). Keep the carbon
brushes clean and free to slip in the holders.
Both carbon brushes should be replaced at
the same time. Use only identical carbon brushes.
Use a screwdriver to remove the brush holder caps. Take out the worn carbon brushes
insert the new ones and secure the brush holder caps. (Fig. 10)
※ Damaged cord must be replaced by a special cord purchased from authorized service
center.
※ To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or
adjustment should be performed by authorized service centers, always using original
replacement parts.