Features
● Counting speed: 1cps / 30cps / 2kcps / 5kcps
● Selectable voltage input (PNP) method or
no-voltage input (NPN) method
● Input mode: Up, Down, Up/Down
● Dot for Decimal Point / Hour. Min. Second by RESET key
● Wide range of input power supply
: 100-240VAC 50/60Hz,
24VAC 50/60Hz, 24-48VDC universal
● Selectable Counter or Timer function by internal DIP switch
● Changed case color (ivory → black)
● [Counter]
20 input modes
● [Timer]
Various time setting range-6-digit model: 0.01 sec to 99999.9 hour /
● Output: Indicator
Please read "Safety Considerations"
in the instruction manual before using.
Models
Model
Display digit
FX4Y-I2
9999 (4-digit)
FX4Y-I4
FX6Y-I2
999999 (6-digit)
FX6Y-I4
Specifications
Model
Indicator
Display digit
Character size (W×H)
Power supply
Permissible voltage range
Power consumption
Max. counting speed of CP1/CP2 Selectable 1cps / 30cps / 2kcps / 5kcps (DIP switch)
Return time
Min. signal width
Input method
Repeat/Set/Voltage/Temp. error Max. ±0.01% ±0.05 sec
Insulation resistance
External power supply
Memory retention
Dielectric strength
AC voltage
Noise
immunity
AC/DC voltage ±500V the square wave noise (pulse width 1㎲) by noise simulator
Mechanical
Vibration
Malfunction
Mechanical
Shock
Malfunction
Ambient temp.
Environment
Ambient humi.
Protection structure
Approval
※ 1
Weight
※ 1: The weight includes packaging. The weight in parenthesis is for unit only.
※ Environment resistance is rated at no freezing or condensation.
4-digit model: 0.01 sec to 9999 hour
Size
DIN W72×H36mm
FX4Y-I2
FX4Y-I4
4-digit
8×14mm
24VACᜠ 50/60Hz,
100-240VACᜠ 50/60Hz
24-48VDCᜡ
90 to 110% of rated voltage
Max. 2.8VA
Max. 3.8VA
(24VACᜠ 50/60Hz),
(240VACᜠ 50/60Hz)
Max. 1.8W (24-48VDCᜡ)
Max. 500ms
INHIBIT, RESET: approx. 20ms
Selectable voltage input (PNP) method or no-voltage input (NPN) method
[Voltage input (PNP) method]-input impedance: max. 10.8kΩ, [H]: 5-30VDCᜡ, [L]:0-2VDCᜡ
[No-voltage input (NPN) method]-short-circuit impedance: max. 470Ω, short-circuit residual voltage: max. 1VDCᜡ,
open-circuit impedance: min. 100kΩ
Over 100MΩ (at 500VDC megger)
Max. 12VDCᜡ ±10% 50mA
Approx. 10 years (non-volatile memory)
2,000VAC 50/60Hz for 1 min (between all terminals and case)
±2kV the square wave noise (pulse width 1㎲) by noise simulator
0.75mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 1 hour
0.5mm amplitude at frequency 10 to 55Hz (for 1 min) in each X, Y, Z direction for 10 min
2
300m/s
(approx. 30G) in each X, Y, Z direction for 3 times
2
100m/s
(approx. 10G) in each X, Y, Z direction for 3 times
-10 to 55℃, storage: -25 to 65℃
35 to 85%RH, storage: 35 to 85%RH
IP40 (front part, IEC standard)
Approx. 175g (approx. 120g)
Output
Power supply
24VAC 50/60Hz, 24-48VDC
100-240VAC 50/60Hz
Indicator
24VAC 50/60Hz, 24-48VDC
100-240VAC 50/60Hz
FX6Y-I2
6-digit
4×8mm
24VACᜠ 50/60Hz,
24-48VDCᜡ
Max. 2.8VA
(24VACᜠ 50/60Hz),
Max. 1.8W (24-48VDCᜡ)
FXY Series
SENSORS
CONTROLLERS
MOTION DEVICES
SOFTWARE
(J)
Temperature
Controllers
(K)
SSRs
(L)
Power
Controllers
(M)
Counters
FX6Y-I4
(N)
Timers
(O)
100-240VACᜠ 50/60Hz