Autonics M4V Series Product Manual - Page 2
Browse online or download pdf Product Manual for Measuring Instruments Autonics M4V Series. Autonics M4V Series 3 pages. Mosaic panel meters for mosaic panels (indicator)

Product Components
• Product
• Bracket × 2
Dimensions
• Unit: mm, For the detailed drawings, follow the Autonics website.
75
■ Bracket
60
Cautions during Wiring
• Unit: mm, Use terminals of size specified below.
≥3.5
≤7.0
Connections
• Measurement input type: 0 - 2 VDCᜡ, 1 - 5 VDCᜡ, 0 - 10 VDCᜡ
0 - 2 VDCᜡ,
1 - 5 VDCᜡ,
SOURCE
0 - 10 VDCᜡ
Hi
Low
1
2
3
4
5
6
• Measurement input type: DC 0 - 1 mA
SOURCE
DC 0 - 1 mA
Hi
Low
1
2
3
4
5
6
• Measurement input type: DC 4 - 20 mA
SOURCE
DC 4 - 20 mA
Hi
Low
1
2
3
4
5
6
• Instruction manual
15
91
■ Panel cut-out
≥ 100
+ 0.5
70
0
Specifications
Model
M4V
Input type
DC voltage, DC current
Measurement input
0 - 2 VDCᜡ, 1 - 5 VDCᜡ, 0 - 10 VDCᜡ, DC 0 - 1 mA, DC 4 - 20 mA
type
Max. allowable input
≈ 110 % F.S. for each measured input range
Display method
7 -segment (red) LED (character height: 14 mm)
Dependent on the ambient temperature
Display accuracy
0 to 50 ℃
± 0.2 % F.S. rdg ± 1-digit
-10 to 0 ℃
± 0.3 % F.S. rdg ± 1-digit
Display cycle
0.5 sec
Unit weight
≈ 83 g
Approval
ᜫ
Power supply
12 - 24 VDCᜡ ± 10 %
Power consumption
≤ 2 W
Insulation resistance
≥ 100 MΩ (500 VDCᜡ megger)
Dielectric strength
2,000 VACᜠ 50 / 60 Hz for 1 min
Noise immunity
± 300 V square wave noise (pulse width: 1 ㎲) by the noise simulator
0.75 mm double amplitude at frequency of 10 to 55 Hz (for 1
Vibration
minute) in each X, Y, Z direction for 1 hours
Vibration
0.5 mm double amplitude at frequency of 10 to 55 Hz (for 1 minute)
(malfunction)
in each X, Y, Z direction for 10 min
Shock
300 m/s
(≈ 30 G) in each X, Y, Z direction for 3 times
2
Shock (malfunction)
100 m/s
(≈ 10 G) in each X, Y, Z direction for 3 times
2
Ambient temperature
-10 to 50 ℃, storage: -20 to 60 ℃ (no freezing or condensation)
Ambient humidity
35 to 85 %RH, storage: 35 to 85 %RH (no freezing or condensation)