(1) Batch counting under counting mode
When counting alarm output times reaching to the preset batch value , batch alarm output .
When using batch control output , up counting time interval will be more than 10ms
(2) Batch counting under timing mode
When timing alarm output
Under FLK output mode , when the batch counting value is increasing , preset time of Toff and Ton will pass .
Batch output function
If batch output is ON , it will keep
If batch output is ON , the meter power off and power on again , batch output should keep ON status till external reset signal comes.
2.
Modify batch preset vaule
BA
Running mode
Under running status , press
The method of modifying batch output preset value is the same as setting counting value , press
make it flickering . Press
When entering batch preset value modifying mode , the above line LED display the present batch counting value.
When batch preset value is beyong batch counting value , change the batch preset value equal to or smaller than the batch counting value , batch
output will make action.
If batch preset value is set as 0 , batch output is on OFF status .
In batch setting satus , if there is no any operation in 60S , the meter will come back to measure status automatically .
For Example:Pulse number is a number of pulse generated by rotary encoder, L is the measured length, Prescale value is
equal to L divides P.
To use counter and rotary to control length
计数器和旋转编码器控制长度
Roller
滚轮
Rotary encoder
旋转编码器
Motor controlling system
电机控制系统
The diameter of the wheel which connects the rotary coder is 22mm,
The pulses number per 1 revolution of encoder is 1000 pcs.
6.Lock Key Setting
Lock Key function is used for avoiding key mis-pressing.
L.OFF (LOCK OFF): Cancel Lock Key function.
LOC.1(LOCK LEVEL1): Lock RST Key
LOC.2(LOCK LEVEL2): Lock
LOCK.3(LOCK LEVEL3): Lock RST and
times
reaches to the preset batch value , batch alarm output .
status till batch reset signal comes .
ON
Batch preset value modify status
key to enter batch preset value modify status.
BA
key to modify the value , press
刀具
Cutter
Motor
电机
计数器
Counter
and
and
Key.
and
and
Page 04
MD
.
to complete the setting and return to measuring status.
MD
π
×Diameter of the roller( D )
= ---------------------------------
Prescale Value
Pulse number per 1 revolution of the encoder
π×滚轮的直径( D )
系数值 = ------------------------
编码器旋转一周的脉冲个数
3.1416×22
= ------------------
1000
= 0.069mm/pulse
Set 0.069 of prescale value at perscale value ste mode.
Key.
key to select the data need to be modified and
KKCTE02T-A/0-20131221