DynaQuip WaterCopPRO Owner's Manual & Installation Manual - Page 8

Browse online or download pdf Owner's Manual & Installation Manual for Plumbing Product DynaQuip WaterCopPRO. DynaQuip WaterCopPRO 8 pages.

DynaQuip WaterCopPRO Owner's Manual & Installation Manual
10. Position the unit and tighten compression nuts. Hold the
fitting with one wrench while tightening the nut with the
other. Tighten both nuts.
11. Plug unit into a proper power source and turn valve to
open position (open button / green light).
12. Unplug unit, turn water back on and carefully check for
leaks.
13. Tighten fittings if needed to stop any leaks.
14. Plug unit back into power source. Installation is
complete.
Solder Fittings
An alternative method is to solder the unit into the water
line. This method requires a considerably higher skill level
to accomplish the installation properly and safely. If you
are not skilled in this area, it is strongly recommended
that you contact a professional plumber to do this type of
installation.

Electrical Connection

The WaterCopPRO is supplied with a power adaptor.
Consult local electrical codes as to the necessity of
ground fault protection. It is recommended that the
WaterCopPRO not be plugged into an extension cord.
Review "Specification" current and power requirements
as not to overload the circuit supplying power. As with all
sensitive electric equipment, the use of surge protection is
highly recommended.
10 Harris Ind. Pk., St. Clair, MO 63077 • 800-545-3636 • www.watercop.com

Warnings and Precautions

WARNING
The motorized drive unit case is not capable of supporting
any loads. Do not attempt to use the unit as a step. This will
cause damage to the unit and could cause personal injury.
Do not store highly flammable items such as oily rags or
other combustibles near your WaterCopPRO.
CAUTION
It is recommended that eye protection be worn while
installing or servicing the system. Failure to do so could
result in personal injury.
CAUTION
Do not use the case as leverage when mounting this unit or
tightening fittings. Apply wrench to flats on the valve body
to tighten fittings.

Emergency Procedures

In the unlikely event that the WaterCopPRO System should
shut off the main water supply and then become inoperable
due to a power outage or damage, it is possible to manually
operate the WaterCopPRO to return water service. Unplug
the WaterCopPRO from its power source. The valve may be
manually opened by turning the manual override handle in
the direction indicated on the actuator.
DynaQuip Controls
8
192261 rev C