Autonics SCM-WF48 Quick Manual - Page 6
Browse online or download pdf Quick Manual for Media Converter Autonics SCM-WF48. Autonics SCM-WF48 11 pages. Communication converter
Also for Autonics SCM-WF48: Manual (3 pages), Manual (13 pages), Manual (11 pages)
![Autonics SCM-WF48 Quick Manual](/uploads/products/server2/1940714/1940714.png)
SCM Series
Example of connections
SCM-WF48
Cable connection
USB A(Male)
type
Computer
Connection of SCM-WF48 and Multi-drop
B(-)
ON
OFF
A(+)
SCM-WF48
AP mode
Wi-Fi or USB
connection
Computer
Infrastructure mode
Wi-Fi or LAN
connection
Computer
※ One wireless router can connect
max. up to 254 units of SCM-WF48.
※ Before using this unit, set the communication method switch of SCM-WF48 as USB, and connect this unit and a PC with USB cable.
You can set the communication setting for SCM-WF48 by DAQMaster.
S-36
USB Mini 5P
(Male) type
Terminating
resistance (120Ω)
GND
V(12-24VDC)
A(+)
B(-)
A(+)
B(-)
RS485
RS485
DEVICE
DEVICE
#1
#2
RS485
SCM-WF48
Wi-Fi
Wireless router
A B V G
SCM-WF48
B(-)
A(+)
A(+)
B(-)
RS485
...
DEVICE
#30
Connectable max. 31 units of
Autonics products which support
communication
RS485
SCM-WF48
Wi-Fi
RS485
SCM-WF48
+RS485
-RS485
Ground
24VDC
RS485
DEVICE
#31
Connectable max. 31 units of
Autonics products which support
communication
Connectable max. 31 units of
Autonics products which support
communication