High End Systems Universal Controller User Manual Addendum - Page 11
Browse online or download pdf User Manual Addendum for Controller High End Systems Universal Controller. High End Systems Universal Controller 12 pages.
Data Format
This section describes the data format used by the commands described in this addendum.
Channel Voice Message Control
Control Change—used to set the Master Dim level:
1011nnnn
0ccccccc
where
nnnn is the channel number 0 to 15,
ccccccc is the control number 0 to 63,
and
Program Change—used to play back a Preset:
1100nnnn
0ddddddd
where
nnnn is the channel number 0 to 15
and
MIDI Show Control GO command
byte number
1
2
3
4
5
6
7
8
9
The preset number is one or two digits from 1 to 64. Digits are sent as ASCII characters; i.e., 30h
to 39h for the digits 0 to 9. Leading zeros are ignored; for example, preset 2 could be sent as 30h
32h, or simply 32h. Preset 15 would be sent as 31h 35h.
0ddddddd
ddddddd is the desired Master Dim level 0 to 99.
ddddddd is the preset number 1 to 64.
bit pattern
description
11110000
(F0h) Start of System Exclusive
01111111
(7Fh) Universal Real-time SysEx ID
0ddddddd
Device ID
00000010
(02h) MIDI Show Control Sub ID
00000001
(01h) General Lighting Command
Format
00000001
(01h) MSC Go Command
0ccccccc
Cue number ASCII digit 1
0ccccccc
Cue number ASCII digit 2
11111110
(F7h) End of System Exclusive
Addendum UN-1