Autool CT-200 Manual - Page 12
Browse online or download pdf Manual for Cleaning Equipment Autool CT-200. Autool CT-200 18 pages. Injector cleaner & tester
Also for Autool CT-200: User Manual (14 pages), User Manual (14 pages)
12 Non-dismantle Cleaning
1) T ake the red long hose from the accessories box. Connect one end to
return hose of the engine, and the other end to the return hose port of
the machine.
2) Run the engine, and check the test fluid bottle. When the level is up to
600-800ML, stop the engine.
3) T ake the long blue hose from the accessory box. Connect one end to
the high pressure port of the machine, and the other end to the supply
hose of the engine fuel system.
4) Move the pump relay of the engine or short connect the fuel circuit of
the engine fuel pump. (In this case, please make sure the cover of fuel
tank is open.)
5) Turn on the machine. Press Left or Right Arrow key to select
Non-dismantle Cleaning, and set up the time as 20-30minutes.
6) Adjust system pressure, (normally the pressure should between
0.25-0.3Mpa).
7) Press RUN key, and turn on the engine after several seconds.
8) Pour Non-dismantle cleaning fluid into one of the measuring cylinder
of the machine (0.5 bottle for 4 cylinder engine, 0.75 bottle for 6
cylinder engine, and one bottle for 8 cylinder engine).
9) Adjust engine speed, make it to run 1-10 minute under idle speed,
10-15 minutes under medium and high speed;, and run under idle
speed again in the rest of the time.
10) When the setting time is zero, the machine will stop automatically.
- - 12 - -