FB2200 Flow Computer 8-Channel Expansion I/O Board Field Replacement Guide
1
Screws
2
Posts
6.
Carefully place the new (replacement) 8-channel expansion I/O board on the posts, and
gently press it down onto the I/O termination board. Attach it using the four screws you
removed in step 5. Torque screws to 1 to 2 in-lbs. (0.1 to 0.2 N-m).
7.
Take the CPU enclosure (with the HMI module attached) and line up the CPU enclosure's
captive fastening screws with their matching holes on the I/O assembly. Press the enclosure
screws onto the holes and hold it there while tightening each of the captive fastening screws.
Torque screws to 7 to 9 in-lbs. (0.8 to 1.0 N-m).
8.
Connect the intermediate cable to the sensor module and make sure it has clearance.
9.
Plug in TB2 (pins 1,3,5,7) to restore power.
10.
Close the enclosure door.