Autopilot APCETHD Manual - Page 6
Browse online or download pdf Manual for Controller Autopilot APCETHD. Autopilot APCETHD 18 pages.
Page 5
Error LEDs
The APCETHD is smart enough to monitor the temperature and
humidity levels and to alert the user to a problem with any of the
devices connected to the APCETHD. Here is how it works.
As the unit functions normally, the environmental conditions
(temp & humidity) will be slowly but steadily changing. These
small changes are detected by the controller.
If the controller does not detect a slight change in one (or more)
environmental conditions within a 1-hour period, the unit will de-
activate the affected output and the appropriate green Error LED
will be flashing to indicate which device may have a problem.
This safety feature is extremely important and useful to
eliminate "runaway" conditions which could result in crop damage
or other more serious problems.
If any of the Error LEDs are blinking, the user should refer to the
example below to help identify the actual cause of the error.
* EXAMPLE: The Cooling error LED is flashing, it means that
the device connected to the Cooling output either did not
turn on OR that there is a problem with the temperature
sensor. Check the cooling device for proper operation and
verify the remote sensor is reading properly.
Note:
To reset an error, press the Enter / reset button.
APCETHD