ACTOP VDP311 User Manual - Page 4

Browse online or download pdf User Manual for Intercom System ACTOP VDP311. ACTOP VDP311 8 pages. Video intercom and doorphone system

You can use any 4-core cable to make these connections, but screened and/or
armoured cables are most secure. To connect additional monitors you will need
to use 5-core cables to prevent interference between the monitors – only the
monitor that accepts the call will be in communication with the caller. It is
possible to use 4-cores for the signal and the screen for the ground connection.
The monitors and door cameras are each provided with terminals and a short
cable with appropriate terminal connectors already attached. Use screw-type
terminal blocks to connect to these, or use a soldered joint if you are suitably
experienced. You can also purchase lengths of cable with terminal connectors
already attached.
Connect similar colours together. That is, connect red to red, blue to blue, yellow
to yellow and white to white. The green wire does not need to be connected
(unless you have additional monitors or additional doors) and should be on the
left of the terminal block when looking at the rear of the unit as in the image in
section 1.
A power adaptor must be plugged into the monitor. This will also supply power
to the door camera unit.
The (optional) electronic lock is connected to the door camera unit, using a twin
cable.
Interface Cable Description:
1. Yellow (Video)
2. Black (Ground)
3. Blue (Audio)
4. Red (+12V DC)
P a g e
4