Dynatech iTronix X-C 6250 Technical Bulletin - Page 2

Browse online or download pdf Technical Bulletin for Laptop Dynatech iTronix X-C 6250. Dynatech iTronix X-C 6250 2 pages. Cradle contact cable assembly replacement procedure

5. Firmly grasp the brass coaxial connector and disconnect the coaxial cable from the cradle contact assembly.
Brass Coaxial Connector
6. The L base may now be lifted away from the rest of the cradle and set aside.
7. Remove the two screws and two washers holding the cradle contact assembly to the cradle case.
8. Remove the contact assembly by pushing it out through the top of the case.
9. Install the replacement cradle contact cable through top of the case.
10. The plastic portion of the cradle contact cable assembly is keyed and will only fit onto the cradle case holding tabs if it is in
the correct orientation.
Brass Coaxial Connector
11. Position the cradle contact assembly and install the two screws and two washers that hold the cradle contact assembly to
the cradle case.
12. Install the cradle contact cable connector onto the cradle PCB it is also keyed to connect in one orientation only. Ensure
that the locking mechanism retains the connection.
13. Slide the L base onto the case from the rear to ensure that the power switch is in the correct position.
14. Re-install the 14 screws on the bottom and rear of the cradle.
15. Connect power to the cradle and verify unit charges after assembly (switch on/off and charging of X-C 6XXX, external RF
connection). Ensure unit shows charger in battery status screen.
WARNING Use ESD precautions when replacing cradle parts. Tampering with the PCB in any way will void factory
warranty.
Page 2
Cradle Contact Assembly
Cable to PCB
Connector (Male)
97-0051-001
09/99